5490689-LTG-F-0620
8
Johnson Controls Unitary Products
— = Not applicable.
HL19B3621S
MVC20DN21
24.5
CF/CM42D
1
825
29.6
21.8
18.00
27.00
28.80
–
–
–
3.30
–
HL19B3621S
MVC20DN21
24.5
CF/CM42D
2
1175
35.4
28.2
–
13.00
35.60
21.80
9.00
8.05
3.44
2.68
HL19B3621S
MVC20DN21
24.5
CF/CM48D
1
825
29.6
21.8
18.00
27.40
24.20
–
–
–
3.80
–
HL19B3621S
MVC20DN21
24.5
CF/CM48D
2
1175
35.4
28.2
–
14.00
35.20
21.80
9.60
8.25
4.10
2.68
HL19B3621S
MVC20DN21
24.5
CF/CM60D
1
825
30.0
22.0
19.00
27.80
24.40
–
–
–
3.24
–
HL19B3621S
MVC20DN21
24.5
CF/CM60D
2
1175
36.0
28.4
–
14.00
36.00
22.40
9.60
8.35
3.72
2.82
HL19B4821S
AE60DX21
24.5
–
1
1200
38.0
29.4
17.00
24.15
30.60
–
–
–
3.72
–
HL19B4821S
AE60DX21
24.5
–
2
1375
46.5
34.8
–
13.00
46.50
30.40
9.60
8.65
4.06
2.98
HL19B4821S
AVC60DX21
24.5
–
1
1075
37.6
28.0
17.00
24.55
30.40
–
–
–
3.66
–
HL19B4821S
AVC60DX21
24.5
–
2
1400
46.5
35.2
–
13.00
46.50
30.60
9.60
8.55
4.02
2.94
HL19B4821S
ME20DN21
24.5
CF/CM64D
1
1300
38.5
30.8
17.00
24.10
30.60
–
–
–
3.78
–
HL19B4821S
ME20DN21
24.5
CF/CM64D
2
1475
47.0
36.2
–
13.00
46.50
30.40
9.60
8.70
4.10
3.00
HL19B6021S
AE60DX21
24.5
–
1
1375
42.5
31.8
16.50
20.70
37.40
–
–
–
3.68
–
HL19B6021S
AE60DX21
24.5
–
2
1550
56.5
41.0
–
13.00
57.50
36.40
9.60
8.15
3.86
2.62
HL19B6021S
AVC60DX21
24.5
–
1
1050
41.0
27.8
16.50
21.00
37.00
–
–
–
3.50
–
HL19B6021S
AVC60DX21
24.5
–
2
1600
56.5
41.0
–
12.50
57.50
37.00
9.60
8.35
3.82
2.72
HL19B6021S
ME20DN21
24.5
CF/CM64D
1
1325
42.5
31.2
16.50
21.30
37.20
–
–
–
3.70
–
HL19B6021S
ME20DN21
24.5
CF/CM64D
2
1675
57.0
42.5
–
13.00
57.50
36.60
9.60
8.50
3.92
2.76
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER
(Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER
(Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
3. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF
(Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP
(Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
SYSTEM CAPACITY - Single Piece and Modular Air Handlers (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
Stage
RATED
CFM
COOLING
2
HEATING
3
MODEL
WIDTH
NET MBH
SEER
EER
NET MBH
HSPF IV
HSPF V
COP
TOTAL
SENS.
47°F OD
17°F OD
47°F OD
17°F OD