Subject to change without notice. Published in U.S.A.
5490689-LTG-F-0620
Copyright © 2020 by Johnson Controls, Inc. All rights reserved.
Supersedes: 5490689-LTG-E-0520
York International Corp.
5005 York Drive
Norman, OK 73069
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
HL19B6021S
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
AIR TEMP.
ENTERING
INDOOR COIL (°F)
ID CFM
1500
1800
2100
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
70.6
4.63
4.47
72.1
4.86
4.35
73.6
5.10
4.23
70
69.4
4.14
4.91
70.7
4.34
4.77
72.0
4.56
4.63
80
68.3
3.74
5.35
69.3
3.91
5.19
70.4
4.10
5.03
47
60
60.3
4.09
4.31
61.5
4.29
4.20
62.7
4.49
4.09
70
58.0
3.56
4.77
59.5
3.75
4.64
60.9
3.95
4.52
80
55.8
3.12
5.23
57.4
3.31
5.09
59.1
3.50
4.95
40
60
53.8
3.80
4.15
54.8
3.95
4.06
55.8
4.11
3.98
70
52.4
3.34
4.59
53.2
3.48
4.48
54.1
3.63
4.37
80
50.9
2.97
5.03
51.7
3.09
4.90
52.4
3.23
4.76
30
60
47.3
3.45
4.01
48.1
3.57
3.95
48.9
3.68
3.89
70
46.0
3.05
4.42
46.7
3.14
4.36
47.3
3.23
4.29
80
44.7
2.72
4.82
45.2
2.78
4.76
45.7
2.85
4.70
17
60
35.2
2.72
3.80
38.8
2.96
3.84
42.3
3.19
3.89
70
36.8
2.56
4.21
39.0
2.76
4.14
41.3
2.97
4.07
80
38.4
2.43
4.63
39.3
2.60
4.44
40.2
2.77
4.25
10
60
29.9
2.38
3.67
34.2
2.67
3.75
38.54
2.95
3.83
70
32.7
2.32
4.12
34.9
2.47
4.14
37.1
2.61
4.17
80
35.5
2.28
4.56
35.6
2.30
4.54
35.7
2.32
4.51
0
60
24.8
2.24
3.24
28.4
2.51
3.31
32.0
2.77
3.38
70
27.1
2.19
3.64
29.0
2.32
3.66
30.8
2.45
3.68
80
29.4
2.14
4.03
29.5
2.16
4.00
29.6
2.18
3.98
-10
60
15.2
1.46
3.05
17.5
1.64
3.12
19.7
1.81
3.18
70
16.7
1.43
3.42
17.8
1.51
3.44
18.9
1.60
3.46
80
18.1
1.40
3.79
18.1
1.41
3.77
18.2
1.42
3.75
-20
60
9.3
0.94
2.89
10.6
1.05
2.95
12.0
1.16
3.01
70
10.1
0.91
3.24
10.8
0.97
3.26
11.5
1.03
3.28
80
11.0
0.90
3.59
11.0
0.90
3.57
11.1
0.91
3.55
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS - 5 TON
Air Handler
Coil
MBH
COP
KW
AE60DX21
–
1.00
1.02
0.98
AVC60DX21
–
1.00
1.01
0.99
ME20DN21
CF/CM64D
1.00
1.03
0.97
MVC20DN21
CF/CM64D
1.00
1.00
1.00
FURNACE MULTIPLIERS - 5 TON
Furnaces
Coil
T.C.
S.C.
KW
TM8V100C20MP12C
CF/CM64D
1.00
1.00
1.00
TM8V120C20MP12C
CF/CM64D
1.00
1.00
1.00
TM8X100C20MP11
CF/CM64D
1.00
1.00
1.00
TM8X120C20MP11
CF/CM64D
1.00
1.00
1.00
TM8Y100C20MP11
CF/CM64D
1.00
1.00
1.00
TM8Y120C20MP11
CF/CM64D
1.00
1.00
1.00
TM9E100C20MP11
CF/CM64D
0.99
0.98
1.02
TM9E120D20MP11
CF/CM64D
0.99
1.00
1.01
TM9V100C20MP12C
CF/CM64D
0.99
0.99
1.01
TM9V120D20MP12C
CF/CM64D
0.99
1.00
1.01
TM9Y100C20MP11
CF/CM64D
0.99
0.98
1.02
TM9Y120D20MP11
CF/CM64D
0.99
1.00
1.01
TMLV100C20MP12C
CF/CM64D
1.00
1.00
1.00
TMLV120C20MP12C
CF/CM64D
1.00
1.00
1.00
TMLX100C20MP11
CF/CM64D
1.00
1.00
1.00
TMLX120C20MP11
CF/CM64D
1.00
1.00
1.00
TP9C100C20MP13C
CF/CM64D
0.99
0.99
1.01
TP9C120D20MP13C
CF/CM64D
0.99
1.00
1.01
TPLC100C20MP13C
CF/CM64D
1.00
1.00
1.00
TPLC120C20MP13C
CF/CM64D
1.00
1.00
1.00
LP9C100C20MP13C
CF/CM64D
0.99
0.99
1.01
LP9C120D20MP13C
CF/CM64D
0.99
1.00
1.01
LPLC100C20MP13C
CF/CM64D
1.00
1.00
1.00
LPLC120C20MP13C
CF/CM64D
1.00
1.00
1.00
FURNACE MULTIPLIERS - 5 TON (Continued)
Furnaces
Coil
T.C.
S.C.
KW