It is absolutely forbidden for the user to connect the air discharge of the appliance,
when used a suction use, to boiler chimneys, gas, fume or vapour scavenging
chimneys or any other duct, even only ventilation ducts, which have been used or will
be used for other devices. Moreover it is not permitted to connect the scavenging
pipe for fumes in other adjacent rooms or wellholes, or pipes for fire-fighting devices.
In any case it is necessary to respect all norms concerning scavenging of the air. Any
user who does not adhere to these instructions is risking his own life and the lives of
others. In this case, the manufacturer declines any responsibility.
It is necessary for qualified personnel to make a hole for ventilation on the outside wall.
MOUNTING INSTRUCTIONS
Mount the appliance as shown in the pictures.
The appliance is equipped with standard fixing material. The person who is mounting
the hood should make sure that the fixing elements are right and suitable for the walls
and ceilings he finds. The manufacturer declines any responsibility for damages
caused by incorrect mounting.
The packaging material is dangerous for childen. Never allow the children to play with the
packaging material.
During the installation of the appliance, always wear protective handgloves to prevent
injuries.
DISMANTLING AND REPOSITIONING OF THE FILTERS
■
Switch the light off and wait untill the bulbs are completely cooled down.
■
Follow the steps as shown in the pictures.
■
To dismantle the metal filters, press the handles, overturn the filters and remove
them.
■
To remount the metal filters, put the rear part of the metal filter into its seat, press
the handle, insert the front part of the filter and release the handles.
GENERAL WARNING
The pipe must be heat, flame and corrosionproof. The manufacturer strongly advises
against the use of reducers or pipes with different diameter to the appliance outlet pipe,
and pipes made of flexible aluminium because performance is diminished and noise level
increased.
The end part of the pipe, on the outside of the hole on the wall, must be of such a shape
to avoid rain, gusts of wind or other foreign bodies getting into the pipe. Should there be
any doubt, contact anyone specialising in the installation of gas or ventilation system.
ELECTRICAL CONNECTION
WARNING
The electrical connection can only be carried out by qualified professional personnel,
using standard material and state of the art installation methods. The manufacturer
declines any responsibility for installations carried out by unskilled persons and for
installations which are not in conformity with the standard norms concerning electrical
safety (both concerning methods and materials).
4
Summary of Contents for LA-350
Page 1: ...Instruction manual LA 350 650 950 Small Ceiling Hood...
Page 10: ...2 25 m 0 15 m 2 25 m 0 15 m 0 6 m 0 6 m 0 6 m A 220 240 Vac TRAFO 12Vdc OK NO M 3...
Page 11: ...2 25 m 0 15 m 2 25 m 0 15 m 0 6 m 0 6 m 0 6 m 2 25 m 1 2 m 1 2 m 1 2 m B C M 3...
Page 12: ...M 5 M 4 2 12 Vdc PL PM PS 3 4 5 6 OPTIONAL...
Page 13: ...M 7 M 6 9 8 7 10 12 11 10 12 12 12...
Page 14: ...M 8...