Luxair LA-350 Installation Manual Download Page 3

 It is absolutely forbidden for the user to connect the air discharge of the appliance, 

when used a suction use, to boiler chimneys, gas, fume or vapour scavenging 
chimneys or any other duct, even only ventilation ducts, which have been used or will 
be used for other devices. Moreover it is not permitted to connect the scavenging 
pipe for fumes in other adjacent rooms or wellholes, or pipes for fire-fighting devices. 
In any case it is necessary to respect all norms concerning scavenging of the air. Any 
user who does not adhere to these instructions is risking his own life and the lives of 
others. In this case, the manufacturer declines any responsibility. 

It is necessary for qualified personnel to make a hole for ventilation on the outside wall. 

MOUNTING INSTRUCTIONS 

Mount the appliance as shown in the pictures. 

 The appliance is equipped with standard fixing material. The person who is mounting 

the hood should make sure that the fixing elements are right and suitable for the walls 
and ceilings he finds. The manufacturer declines any responsibility for damages 
caused by incorrect mounting. 

The packaging material is dangerous for childen. Never allow the children to play with the 
packaging material. 
During the installation of the appliance, always wear protective handgloves to prevent 
injuries. 

DISMANTLING AND REPOSITIONING OF THE FILTERS

 

Switch the light off and wait untill the bulbs are completely cooled down.

Follow the steps as shown in the pictures.

To dismantle the metal filters, press the handles, overturn the filters and remove
them.

To remount the metal filters, put the rear part of the metal filter into its seat, press
the handle, insert the front part of the filter and release the handles.

GENERAL WARNING 

The pipe must be heat, flame and corrosionproof. The manufacturer strongly advises 
against the use of reducers or pipes with different diameter to the appliance outlet pipe, 
and pipes made of flexible aluminium because performance is diminished and noise level 
increased. 
The end part of the pipe, on the outside of the hole on the wall, must be of such a shape 
to avoid rain, gusts of wind or other foreign bodies getting into the pipe. Should there be 
any doubt, contact anyone specialising in the installation of gas or ventilation system. 

ELECTRICAL CONNECTION 

WARNING 

The electrical connection can only be carried out by qualified professional personnel, 
using standard material and state of the art installation methods. The manufacturer 
declines any responsibility for installations carried out by unskilled persons and for 
installations which are not in conformity with the standard norms concerning electrical 
safety (both concerning methods and materials). 

Summary of Contents for LA-350

Page 1: ...Instruction manual LA 350 650 950 Small Ceiling Hood...

Page 2: ...acing wall suitably positioned and dimensioned If in doubt national and international standards precisely indicate the rules for the state of art installation of gas systems and for environment air ch...

Page 3: ...nce always wear protective handgloves to prevent injuries DISMANTLING AND REPOSITIONING OF THE FILTERS Switch the light off and wait untill the bulbs are completely cooled down Follow the steps as sho...

Page 4: ...h the transformer unit supplied with the appliance and must be connected only to a very safety low tension corresponding to the marking on the appliance Wiring diagramm Connect the wires of the second...

Page 5: ...if it is wished to install the transformer unit with a plug it is necessary that you have access to the plug always turn off the main voltage supply by means of the bipolar switch before connecting an...

Page 6: ...10 minutes the motor reduces the speeds in automatic way If you press this push button it reduces the speeds until the lowest speed is raached If you press this push button it stops the motor If you...

Page 7: ...ilters are very dirty the motor can only take in a small quantity of air and performance is reduced CLEANING To preserve the apliance in good condition clean this periodically following the advice giv...

Page 8: ...ronic Equipment WEEE This norm is the frame of a European wide validity of return and recycling of Waste Electrical and Electronic Equipment The symbol on the product or on its packaging indicates tha...

Page 9: ...M 2 M 1 120 120 1 120 200 150 180 180 X kg 50 SHOWAIR 300 SHOWAIR 600 SHOWAIR 900 X 335 550 650 Model...

Page 10: ...2 25 m 0 15 m 2 25 m 0 15 m 0 6 m 0 6 m 0 6 m A 220 240 Vac TRAFO 12Vdc OK NO M 3...

Page 11: ...2 25 m 0 15 m 2 25 m 0 15 m 0 6 m 0 6 m 0 6 m 2 25 m 1 2 m 1 2 m 1 2 m B C M 3...

Page 12: ...M 5 M 4 2 12 Vdc PL PM PS 3 4 5 6 OPTIONAL...

Page 13: ...M 7 M 6 9 8 7 10 12 11 10 12 12 12...

Page 14: ...M 8...

Page 15: ...the remote control please ask a qualified electrician for advise or simply order the switch unit direct for Luxair see spares section on our website Your ceiling extractor is already pre wired to the...

Page 16: ...ting it at you extractor 3 whilst keeping your finger on the button now turn the power back on to your fan keep the pressed all the time you will hear a BEEP to confirm the unit has accepted the code...

Page 17: ...ith Luxair within 21 days of installation either or by mail A 12 month parts and labour warranty is standard without product registration but proof of purchase may be required Please note the 2 years...

Reviews: