Installation Settings Guide

-10 Minimum On/Off Time

-11 Temperature Swing

Use this setting to set a swing value. Your swing setting determines how far the ambient 

  Temperature can deviate from the set temperature before KONOz turns on your heating 

  or cooling system. You can select 0, .25°, .5°, 1° or 2.25°.

Use this setting to set a standby time so that your HVAC systems can safely and efficiently    

   switch on and off. You can either select a 5-minute or a 2-minute off time. During normal 

   operation, the hourglass icon indicates that the minimum off time is temporarily preventing 

   your heating and cooling system from turning on.

-12 Stage 2 Heating Offset (for conventional systems)

Use this setting to set a value that your thermostat will use to decide when to turn on your 

  second stage of heating. You can select Off, 1, 2, 3, 4 or 5 degrees F.

Off, no second stage heat

All manuals and user guides at all-guides.com

Summary of Contents for KONOz

Page 1: ...next option There are three ways to exit the settings 1 Continue through the remaining settings until you pass setting 99 2 Press and hold the knob for 3 seconds after you confirm any changes to your...

Page 2: ...ration temperature and the offset value to remove calibration make sure that the offset value is set to 0 03 Available HVAC Modes Heat Only Heat Cool KONOz uses terminal detection to identify your sys...

Page 3: ...mum Heat Limit Default Temperature 45 F Use this setting to set a minimum temperature limit for your heating system The minimum heat limit range is from 60 F 15 C to as low as 45 F 7 C Note Not availa...

Page 4: ...Gas Furnace Electric Furnace Boiler No Fan and Heat Pump See step 09 below for additional options when selecting Heat Pump 09 System Type Heat Pump If you selected heat pump during 8 you will then hav...

Page 5: ...C systems can safely and efficiently switch on and off You can either select a 5 minute or a 2 minute off time During normal operation the hourglass icon indicates that the minimum off time is tempora...

Page 6: ...to choose between 12 hour am pm time display or 24 hour time display Note This setting not available with battery only power 15 Backlight Use this setting to choose between a backlight auto off settin...

Page 7: ...ys 98 Compressor Bypass Use this setting to temporarily disable the minimum on off time protection If you set compressor bypass protection to yes then your system will switch heating and cooling on of...

Page 8: ...control of KONOz When locked press and hold the knob for 10 seconds to unlock Power Cycle Remove KONOz from its base and locate the black reset button on the back of the thermostat Press and hold this...