Installation Settings Guide
-07 Minimum Cool Limit
Use this setting to set a minimum temperature limit for your cooling system. The minimum
cool limit range is dependent on the values you entered for your heating and cooling limits.
-08 System Type
Use this setting to modify the system type. The available options include Gas Furnace, Electric
Furnace, Boiler (No Fan) and Heat Pump. See step 09 below for additional options when
selecting Heat Pump.
-09 System Type - Heat Pump
If you selected heat pump during #8, you will then have to select your valve type in #9. Select
O or B depending on your valve type. B will energize the B/O terminal in heat mode and O
will energize the B/O terminal in cool mode.
Gas Furnace
Electric Furnace
Boiler (No Fan)
Heat Pump Option
O Valve
B Valve
Default Temperature: 50°F