background image

© COPYRIGHT 20

1

6 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

I M P O R TA N T !

Please read all instructions carefully before beginning 

installation and save for future reference.  Before 

removing any wiring from your existing thermostat, its 

wires must be labeled with their terminal designations.  

Ignore the color of the wires since they may not 

comply with any standard.

Thank you for your confidence in our product. To obtain the best results 

from your investment, please read this manual and acquaint yourself with 

your purchase before installing your new thermostat. Then follow the 

installation procedures, one step at a time. This will save you time and 

minimize the chance of damaging the thermostat and the systems it 

controls. These instructions may contain information beyond that required 

for your particular installation. Please save for future reference.

INSTALLATION AND OPERATING 

INSTRUCTIONS

COMPATIBILITY

The unit can be used with 

most 24 volt gas, oil or electric 

heating and air conditioning 

systems, gas millivolt heating 

systems, and single stage heat 

pumps. It cannot be used with 

120 volt heating systems or two 

stage heat pumps. Ask your 

dealer for other 

TradePro

 

thermostats to control those 

systems.

FEATURES

Vertical or Horizontal Orientation

Large easy to read backlit display

Mode and Fan control for ease of use

Simple Temperature UP and Down

Control.

Calibration control

Temperature Swing adjustability (9

levels)

2 or 5 minute compressor delay

Fahrenheit or Celsius selection

Temperature Limits for High and Low

selections

Test mode to temporarily disable the

compressor delay

TEMP UP

MODE

FAN

TEMP DOWN

WARNING: Use Energizer

® 

or DURACELL

® 

Alkaline 

Batteries Only. 

Energizer

® 

is a registered trademark of Eveready 

Battery Company, Inc. DURACELL

® 

is a registered trademark of 

The Gillette Company, Inc.

Patent # 6,951,306

In the winter, set the system switch to 

HEAT

 to control your heating 

system.

In the summer, set the switch to 

COOL

 to control your air conditioner.

Press either the 

TEMPERATURE UP

 or 

DOWN

 key in order to show

the current 

SET TEMPERATURE

.

Press 

TEMPERATURE UP

 or 

DOWN

 keys again until your desired 

temperature is displayed. The display will show the current room

temperature again after two seconds.

Press the light bulb button to illuminate the display. Adjusting the 

temperature will keep the display lit until no button has been pressed for 

over ten seconds.

In spring and fall or when windows are open, you can set the system 

switch to 

OFF

.

Setting the 

FAN

 switch to 

AUTO

 automatically runs your system’s fan 

during heating and cooling.

Setting the 

FAN

 switch to 

ON

 runs your system’s fan continuously even 

without heating or cooling.

N O T E

The FAN switch works only if your system provides a wire for the

thermostat’s “G” terminal.

INSTALLATION

Please read all instructions carefully before beginning installation.

C A U T I O N

Turn off electricity to the appliance before installing or

 

servicing thermostat or any part of the system. Do not turn

 

electricity back on until work is completed.

Do not short (jumper) across electric terminals at control on furnace or 

air conditioner to test the system. This will damage the thermostat and 

void your warranty.

All wiring must conform to local codes and ordinances.

This thermostat is designed for use with 24 volt and millivolt systems.

The thermostat should be limited to a maximum of 1.5 amps; higher

current may cause damage to the thermostat. If you are in doubt, call 

your HVAC contractor.

Your thermostat is a precision instrument. Please handle it with care.

OFF

TOOLS REQUIRED

MODE

 

On replacement installations, mount the new thermostat in place of the 

old one unless the conditions listed below suggest otherwise. On new 

installations, follow the guidelines listed below.

Remember that your 

TP-L111

 may be mounted vertically or

horizontally

 

when determining the optimal location.

Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the

floor, and in a room that is used often.

Do not install it where there are unusual heating conditions, such as: in

direct sunlight; near a lamp, radio, television, radiator, register, or 

fireplace; near hot water pipes in a wall; near

 

a stove on the other side

of a wall

.

Do not locate in unusual cooling conditions, such as: on a wall

separating an unheated room; or in a draft from a stairwell, door, or

window.

Do not locate in a damp area. This can lead to corrosion that will

shorten thermostat life.

Do not locate where air circulation is poor, such as: in a corner or an

alcove; or behind an open door.

Do not install the unit until all construction work and painting has been 

completed.

OPERATING INSTRUCTIONS

#1 Phillips screwdriver (small)

Wire Stripper

Drill

THERMOSTAT LOCATION

TP-L

111

DIGITAL ELECTRONI

C

 THERMOSTAT

Summary of Contents for TP-L111

Page 1: ...lluminate the display Adjusting the temperature will keep the display lit until no button has been pressed for over ten seconds In spring and fall or when windows are open you can set the system switch to OFF Setting the FANswitch to AUTO automatically runs your system s fan during heating and cooling Setting the FANswitch to ON runs your system s fan continuously even without heating or cooling N...

Page 2: ...OLT SYSTEMS AC LINE 24 VAC XFMR OPTIONAL COMMON GAS VALVE TYPICAL 3 WIRE HEAT HOOKUP WHERE THIRD WIRE IS FAN WIRE AC LINE 24 VAC XFMR FAN OPTIONAL COMMON GAS VALVE TYPICAL 4 WIRE HOOKUP HEATING AND COOLING AC LINE 24 VAC XFMR FAN COOL COMPRESSOR OPTIONAL COMMON GAS VALVE TYPICAL 5 WIRE HOOKUP HEATING AND COOLING AC LINE 24 VAC 24 VAC XFMR AC LINE XFMR FAN COOL COMPRESSOR OPTIONAL COMMON TYPICAL SI...

Page 3: ...be accessed and selected by navigating through the MENU screen The instructions below detail all the options under the MENU screen a CAL Calibration b SWNG Temperature Swing c DELY Delay d F C Fahrenheit and Celsius Selection e TLMT Temperature Limit f TEST Test Mode g EXIT Exit 1 Access the Menu Screen In the off position press Up and Down simultaneously approx 3 seconds until the MENU screen is ...

Page 4: ...L Alkaline Batteries Only 1 Press and hold the Up and Down button simultaneously at the F C selection 2 Press Up or Down to select the F or C 3 Once the value is selected press and hold the Up and Down button simultaneously to select the value FAHRENHEIT AND CELSIUS 1 Press and hold the Up and Down button simultaneously at the TLMT selection 2 Press Up or Down to select the Heat limit then press U...