N O T E
If you have an electric system and the blower does not operate after
installation, find the electric/gas heat jumper on the back of the body as
indicated in the following diagram. Move the jumper from the center and
right pins, to the center and left pins.
C A U T I O N
Do not allow wires to touch each other or parts on thermostat.
Terminated wires must be trapped between black spacer and
brass terminal. Securely tighten all 8 electrical terminal screws.
OPEN
:
In this position, the RH and RC terminals
are not
shorted.
RH
=
RC:
In this position, the RH and RC terminals
are
shorted
.
GAS:
In this position, the thermostat is set for GAS furnace
operation.
ELECT:
In this position, the thermostat is set for Electrical furnace
operation
JUMPER Settings
There are 2 Basics steps involving jumper settings:
1.
Move the Jumper to the
appropriate position as
described below.
2.
After making all the jumper
selections, press the Reset
(RST)
button.
HORZ
:
Sets the thermostat in a Horizontal orientation.
VERT
:
Sets the thermostat in a Vertical orientation
.
Multiple Features can be accessed and selected by navigating through
the MENU screen. The instructions below detail all the options under the
MENU screen
:
a. CAL: Calibration
b. SWNG: Temperature Swing
c. DELY: Delay
d. F/C: Fahrenheit and Celsius Selection
e. TLMT: Temperature Limit
f. TEST: Test Mode
g. EXIT: Exit
1.
Access the Menu Screen
: In the off position, press Up and Down
simu
ltaneously
(approx. 3 seconds) until the MENU screen is displayed
MENU
1.
Press and
h
old the Up and Down button simultaneously at the CAL
selection.
2.
Press Up or Down to select the Calibration amount (-5F to +5F
increments)
3.
Once the desired calibration point is reached, press and hold the Up
and Down button simultaneously to select the
value
CALIBRATION
1.
Press and
h
old the Up and Down button simultaneously at the
SWNG
selection.
2.
Press Up or Down to select the
Swing setting
(
0.25 to 2.25
increments)
3.
Once the desired
swing
point is reached, press and hold the Up
and
Down button simultaneously to select the
value
TEMPERATURE SWING
1.
Press and
h
old the Up and Down button simultaneously at the
DELY
selection.
2.
Press Up or Down to select the
5 Minute or 2 Minute Compressor
delay
3.
Once the desired
delay
point is reached, press and hold the Up
and
Down button simultaneously to select the
value
COMPRESSOR DELAY