background image

HEAT-PUMP (COMPRESSOR) STYLE HEAT/COOL SYSTEM 

[typical wire color used]

R (or RC/RH) 

24(+) VAC Power, Cool  

[RED]

Reversing Valve 

[ORANGE]

Y1 

Heat Pump Outdoor Unit 

[YELLOW]

Blower Fan 

[GREEN]

W2 

Auxiliary/Emergency Heat 

[WHITE]

24(-) VAC Common 

[BLUE]

B** 

Reversing Valve (only if no “O” wire- 

[

can vary per each installation

]

 

 

ie: Rheem/Ruud/Bard systems)

Note: There should NOT be a wire used on the W1 wire connection at terminal.

** IMPORTANT: If you have both an O wire and B wire (ie: Trane system), please install B to the “C” terminal

4.1b Wiring Terminal Reference: Heat Pump Systems (without LUX Power Bridge)

Referencing your wiring photo, attach your thermostat wires to the LUX/GEO using your original wiring 

letters and the following terminal reference as a guide based upon your system type.

GAS / OIL / ELECTRIC FURNACE and/or AIR CONDITIONING 

[typical wire color used]

RH (or R) 

24(+) VAC Power, Heat 

[RED]

W1 

1st Stage Heat 

[WHITE]

Blower Fan 

[GREEN]

24(-) VAC Common 

[BLUE]

Y1 

1st Stage Cool 

[YELLOW]

(other)

RC 

24(+) VAC Power, Cool  

[

can vary per each installation

]

Heat Mode Damper 

[

can vary per each installation

]

Cool Mode Damper 

[

can vary per each installation

]

W2 

2nd Stage Heat 

[

can vary per each installation

]

Y2 

2nd Stage Cool 

[

can vary per each installation

]

IMPORTANT:

 If you have both an RC and RH wire present, remove the RED shorting cap inside of GEO 

(the YELLOW shorting cap must only be on one pin, not both).

 

ƒ

Wiring is complete - you may return “cover” between terminal blocks

.

Wiring for methods: #1 C-wire, #3 Micro-USB, and #4 Battery Power

4.1a Wiring Terminal Reference: Conventional Furnace - gas/oil/electric & air-

conditioning (without LUX Power Bridge)

Referencing your wiring photo & terminal guide below, wire to GEO.

IMPORTANT:

 For Heat Pump applications, the YELLOW shorting cap must be across both metal pins 

instead of the default of just one.  Also, there will NOT be a wire connected to the “W1” terminal.

 

ƒ

Wiring is complete - you may return “cover” between terminal blocks

.

Summary of Contents for LUX/GEO

Page 1: ...OU DO NOT HAVE AN iOS OR ANDROID DEVICE PLEASE VISIT LUXGEO COM OR CONTACT LUX SUPPORT GEO Download App and Create Your Account Download your LUX Products App Depending on device type search the App store for LUX Products and create your LUX user account Lux Power Bridge WiFi router For Use On Most 24 volt heating and cooling systems 1 or 2 stage heat 1 or 2 stage cool gas oil or electric furnace ...

Page 2: ...teries included NO YES NO YES NO YES USE Method 1 C Wire refer to Step 4 1 USE Method 2 LUX Power Bridge refer to Step 4 2 USE Method 3 Micro USB see notes on following page USE Method 4 2 Lithium Batteries see notes on following page Do you have home automation devices like Amazon Alexa In your wiring photo from Step 2 do you have a G wire In your wiring photo from Step 2 do you have a C wire Ste...

Page 3: ...B kit with extra long power cable is available from LUX through our www luxproducts com website Refer to Step 4 1 for wiring method Step 4 Remove existing thermostat and wire your LUX GEO AS AN ADDED RESOURCE A GLOSSARY OF TERMS IS AVAILABLE ON LUXGEO COM ALONG WITH VIDEO DEMOS WIRES INSERT INTO SIDE OF TERMINAL UNDER SCREWS HOLD AND PULL TO OPEN GEO Release wires and mounting screws from old ther...

Page 4: ... Heat RED W1 1st Stage Heat WHITE G Blower Fan GREEN C 24 VAC Common BLUE Y1 1st Stage Cool YELLOW other RC 24 VAC Power Cool can vary per each installation B Heat Mode Damper can vary per each installation O Cool Mode Damper can vary per each installation W2 2nd Stage Heat can vary per each installation Y2 2nd Stage Cool can vary per each installation IMPORTANT If you have both an RC and RH wire ...

Page 5: ...onnections are unclear please call LUX Technical Support NOTE When using the Y Splitter pull the orange lever all the way up before inserting your wire Press the lever back down to lock a wire in place AT YOUR FURNACE AIR HANDLER Remove the door panel and locate your control board Use the additional wire labels to identify each wire from your thermostat with its terminal letter on the control boar...

Page 6: ...chnical Support for assistance with your installation Connect your old Y wire to the empty hole next to the blue end of the y splitter 1 Snap the orange lever shut to secure the wire in its place Insert the yellow end of the y splitter into the thermostat s Y terminal and the green wire into the G terminal Move your old G wire to the C terminal on your thermostat Thermostat Thermostat Furnace Furn...

Page 7: ... the Power Bridge s W wire to any terminal block on your control board Connect your old Y wire to the empty hole next to the blue end of the y splitter 1 Snap the orange lever shut to secure the wire in its place Insert the yellow end of the y splitter into the thermostat s Y terminal and the green wire into the G terminal Move your old G wire to the C terminal on your thermostat 2 3 4 Y G R W1 W2...

Page 8: ...xt to the blue end of the y splitter 1 Snap the orange lever shut to secure the wire in its place Insert the yellow end of the y splitter into the thermostat s Y terminal and the green wire into the G terminal Move your old G wire to the C terminal on your thermostat 2 3 4 Y G R W1 W2 C Power Bridge O B Y Rc Rh W1 W2 C G Y C G R 1 W 1 B O Thermostat Thermostat Air Handler Air Handler O B Y Rc Rh W...

Page 9: ...ot use the Power Bridge s W wire for this system Connect your old W wire to the empty hole next to the blue end of the y splitter 1 Snap the orange lever shut to secure the wire in its place Insert the yellow end of the y splitter into the thermostat s W terminal and the green wire into the G terminal Move your old G wire to the C terminal on your thermostat Thermostat Thermostat Furnace Furnace 2...

Page 10: ...sert into base Once GEO front has been secured to base line up and firmly push return power to system Step 6 Configure system settings GEO will guide you through setup Rotate the control wheel to navigate through options and values To make a selection press to go back press GEO will prompt you to select 1 Whether heating and or cooling are connected 2 System type only applies if you have heat Note...

Page 11: ... menu Select the WiFi network that looks like TSTAT xx xx Enter in the password displayed on the thermostat After connecting to TSTAT xx xx return back to the App iOS iOS Android Android 8c Select your home WiFi network enter password iOS Android Once the GEO connects to your home WiFi Network the thermostat will automatically complete steps 3 6 ...

Page 12: ...can work with or without a thermostat schedule to still save energy when away from home Please note and be assured that your GPS location is NEVER reported or known by LUX Products TIP IF YOU SET YOUR FENCE FURTHER FROM YOUR HOME THEN YOUR SYSTEM WILL HAVE MORE TIME TO MAKE YOUR HOME COMFORTABLE BEFORE YOU GET HOME IF YOU SET THE FENCE CLOSER TO HOME THEN YOU WILL SAVE MORE ENERGY BUT SOMETIMES YO...