STEP 6: 

Insert both screws complete to the end, make sure you do not 
perforate the black ‘loop-back’ cable. 

   

 

The result is looking like this: 

 

STEP 7: 

Proceed with next module, starting from step 3. 

Note:

 the installer has to ensure him(her)-self that the screw will 

not perforate any of the cabling, located in the railing! 

Never

 use an electrical tool to fasten the fixing screws in the 

led-unit. 

Summary of Contents for StarGuide MINI 10640

Page 1: ...StarGuide MINI 10640 No control electronics on board...

Page 2: ...TION FROM INJURY 7 3 5 DISPOSING OF THIS PRODUCT 7 4 PHYSICAL INSTALLATION 8 4 1 UNPACKING 8 4 2 LOCATION AND ORIENTATION 9 4 3 MOUNTING 9 4 4 CUTOUT 9 5 EXTERNAL CONNECTIONS 10 5 1 DC POWER INPUT 10...

Page 3: ...StarGuide MINI p 3 25 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 1 Picture 1 1 General...

Page 4: ...StarGuide MINI p 4 25 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 2 Dimensions...

Page 5: ...t you read this manual and insure yourself that you completely understand its content Observe the safety precautions in this manual Install and operate the led unit only as described in this manual an...

Page 6: ...suitable for the application and conform to local regulations Please ensure yourself that the AC to DC current controlled power supply is able to deliver the rated requirements of the complete install...

Page 7: ...orting railing Ensure yourself that the vibration will not loosen the screws which hold the module Take precautions if necessary by applying a low grade locking glue Loctite 222 3 5 Disposing of this...

Page 8: ...efore integrating this card into your installation Installation must be carried out by qualified professionals only 4 1 Unpacking The StarGuide modules are only sold in sets together with their dedica...

Page 9: ...tion This StarGuide MINI led unit itself can be used in all different directions and orientations 4 3 Mounting The StarGuide MINI led unit is designed to be used on a stainless steel tube of 33 7 mm d...

Page 10: ...ity The StarGuide MINI led unit is polarity sensitive So observe polarity and colour cabling Red positive Black negative Power supply Rated current The rated input current of the railing module is 350...

Page 11: ...1 2007 Radiated immunity test EN 61000 4 4 2004 Fast transients and burst immunity EN 61000 4 5 2005 Surge immunity test EN 61000 4 6 2008 Conducted immunity test EN 61000 4 8 1993 Magnetic field immu...

Page 12: ...orized according to EN 60598 as following SELV class III Power supply cord type Z no removal without permanent damage to the unit IP 67 for the StarGuide MINI led unit IK 06 for the StarGuide MINI led...

Page 13: ...works on the installation Power consumption each StarGuide MINI led unit 1 2 W Rated current input 350 mA Forward voltage over the led 2 8 to 3 2 volt depending on binning and color Ingress protection...

Page 14: ...ls The installation of the StarGuide MINI led unit is straightforward and needs mainly two tools Allen key NR 2 Universal Pliers Note A dedicated crimping tool is available to shrink the Scotchlok con...

Page 15: ...red wire is connected with the black wire coming from its neighbor The electrical connection is made with the supplied Scotchlok connectors STEP 1 Insert a black cable at the last cutout direction to...

Page 16: ...cable by using the Scotchlok connector Please note this is the only place where a black cable is connected with another black cable Insert the trimmed wire ends into the connector Do not strip the wi...

Page 17: ...he pliers so the red cap remains flush with the rim of the connector body You will see that a gel which is located in the red cap will be injected in the cable insertions After verifying that the cabl...

Page 18: ...93 35 44 www lux lumen com STEP 4 Make sure both screws are like on following photo and apply some thread locking glue to both screws After applying the glue turn the screws back to approx this situat...

Page 19: ...omplete to the end make sure you do not perforate the black loop back cable The result is looking like this STEP 7 Proceed with next module starting from step 3 Note the installer has to ensure him he...

Page 20: ...circuit will be 12 modules x 3 volt over one module 36 volt It is important to understand that not all current sources are capable of producing a current of 350 mA at 36 volt In this example the powe...

Page 21: ...r on the entire system and allow all electronic devices to discharge and cool down before executing any service or maintenance 8 2 Cleaning The StarGuide MINI Led unit itself Extensive dirt and partic...

Page 22: ...tment will be borne by the customer Limitations Lux Lumen will not warrant the following Periodic check ups maintenance and repair or replacement of parts due to normal wear and tear Consumables Any s...

Page 23: ...h this product Defects caused by improper condition of the power supply network Inadequate packaging of the product when returning it under the RMA procedure Accidents or disasters or any cause beyond...

Page 24: ...l The procedure to obtain a RMA Step 1 Customer contacts Lux Lumen about warranty defects if material has to be returned Step 2 Lux Lumen sends the customer a filled out RMA document using a unique RM...

Page 25: ...rent F Temperature in degrees Fahrenheit C Temperature in degrees Celsius LED Light Emitting Diode SELV Safety extra low voltage mA Milliampere V Volt EN European Norm EMC Electro Magnetic Compatibili...

Reviews: