Determine a Mounting Location
• Mount the WC-2M-GC, WC-4M-GC on a dry, flat indoor
surface such as an electrical closet wall.
• Mount unit in a location that is accessible to allow for
system programming and setup.
• Unit may be mounted in any orientation.
• The unit’s relays will click audibly in normal use. Mount
in a location where this is acceptable.
• The keyholes accept a maximum of 3/16" (5 mm)
mounting bolt. No. 8 (M4) bolt recommended.
• Knockouts are 7/8" (22 mm) in diameter.
12345
ON
STATUS POWER
OPTIONS
Neutral
120V
240V
Motor
Supply
ON
OPEN 1
CLOSE 1
OPEN ALL
CLOSE ALL
OPEN 4
CLOSE 4
OPEN 3
CLOSE 3
OPEN 2
CLOSE 2
SW Live
1B
SW Live
1A
Neutral
SW Live
2B
SW Live
2A
Neutral
SW Live
3B
SW Live
3A
Neutral
SW Live
4B
SW Live
4A
Neutral
9.5 in.
12 in.
6.2 in.
1.25 in.
7.9 in.
.735 in.
AC Motor
Group Controller
Coopersburg, PA 18036 USA
www.lutron.com
500-9575 Rev
. B
®
WC-4M-GC
4 MOTOR GROUP CONTROLLER
110-127 V~ 60 Hz
20 A Max. Input Current
LOAD TYPES
Single Phase, Bi-directional Motor
5 A, 1/4 HP per Channel at 120 V~
TYPES DE CHARGES
Phase Simple, Moteur Bidirectionel
5 A, 1/4 HP par Canal a 120 V~
Listed 243C
Ind. Cont. Eq.
Questions? Call Lutron Technical Support
1-800-523-9466 (24 hrs/7 days)
110-127 V~
USA: Class 2
COM
Open
Stop
Close
COM
Open4
Stop4
Close4
COM
Open3
Stop3
Close3
COM
Open2
Stop2
Close2
COM
Open1
Stop1
Close1
Neutral
120 V
Motor
Supply
Jumper
SW Live
4B
SW Live
4A
Neutral
SW Live
3B
SW Live
3A
Neutral
SW Live
2B
SW Live
2A
Neutral
SW Live
1B
SW Live
1A
Neutral
Line-voltage input power and
motor power wiring entry
Class 2/PELV
wiring entry
2.75 in.
Front View
Side View