Dual Technology Switch with Occupancy Sensor
369773b 4 12.19.13
Maestro
®
Sensor
Load Type and Capacity
Control
Voltage
Load Type
Minimum
Load
Maximum Load
(Anywhere in Gang)
Neutral
Connection
Required
MS-B102
MS-B102-V
120 V
~
Lighting
1, 2
0 A
6 A
1, 2
Yes
Fan
2
4.4 A (1/6 HP)
2
120 - 277 V
~
Lighting
1
6 A
1
MS-B202
120 V
~
Lighting
1, 2
0 A
6 A per circuit
1, 2
Yes
Fan
2
4.4 A (1/6 HP) per circuit
2
120 - 277 V
~
Lighting
1
6 A per circuit
1
1
Sensor switch Load Type: designed for use with permanently installed incandescent, halogen, MLV, ELV, CFL, LED, magnetic fluorescent,
and electronic fluorescent lighting loads.
2
When controlling light and fan loads simultaneously on a single circuit, maximum load capacity per circuit is 4.4 A at 120 V
~
.