Press
Set Zone Levels
Partition Control
Sequencing Control
Set Zone Response to Occupancy Sensors
Select Scene for Occupied State
1.
1.
3.
2.
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold 3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press and hold
3 seconds
Press
Press simultaneously
Assign Zones
2.
Press simultaneously
3.
Press simultaneously
Assign Zones
Enter Partition Programming
Enter Sequencing Programming
Exit Sequencing Programming
Select Input
Press and hold
Press and hold
4.
Press and hold
3 seconds
Exit Partition Programming
Press and hold
Press and hold
Press
Partition Control
Refer to the Installation Instructions provided with the QSE-IO for proper DIP switch settings.
This can be used to join or detach scene activations between zones on an Energi Savr Node
TM
unit and/or GRAFIK Eye
®
QS control
units based on the position of movable walls.
To associate a QSE-IO that is set in a Partition Control configuration to an Energi Savr Node
TM
unit(s):
1.
Enter Partition Control Programming.
Press and hold the
Program
button on the QSE-IO for 3 seconds. The first output LED
will flash indicating “input 1” is selected. The input LEDs on the Energi Savr Node
TM
unit(s) will flash sequentially through each input
group.
2.
Select input.
Tap the
Program
button on the QSE-IO to select an input. Corresponding LED will blink.
3.
Assign zones.
Simultaneously press then release the and buttons on the Energi Savr Node
TM
unit to assign each desired zone
to “input 1” of the QSE-IO. A flashing ‘Zone’ LED indicates an assigned zone.
To unassign zones from the QSE-IO, simultaneously press then release the and buttons for the desired zone. The ‘Zone’ LED will
turn off to indicate the zone is unassigned.
Repeat steps 2 and 3 for each desired QSE-IO input.
4.
Exit Partition Control Programming.
Press and hold the
Program
button on the QSE-IO for 3 seconds to exit.
Sequencing Control
Refer to the Installation Instructions provided with the QSE-IO for proper DIP switch settings.
The Energi Savr Node
TM
unit can be associated to a QSE-IO that is set in Sequencing Control configuration. This can be used to
start and stop automatic sequencing of scenes 5-16.
To associate a QSE-IO that is set in a Sequencing Control configuration to an Energi Savr Node
TM
unit(s):
1.
Enter Sequencing Control Programming.
Press and hold the
Program
button on the QSE-IO for 3 seconds. The first output
LED will flash indicating “input 1” is selected. The input LEDs on the Energi Savr Node
TM
unit(s) will flash sequentially through each
input group.
2.
Assign zones.
Simultaneously press then release the and buttons on the Energi Savr Node
TM
unit to assign each desired zone
to “input 1” of the QSE-IO. A flashing ‘Zone’ LED indicates an assigned zone.
To unassign zones from the QSE-IO, simultaneously press then release the and buttons for the desired zone. The ‘Zone’ LED will
turn off to indicate the zone is unassigned.
3.
Exit Sequencing Control Programming.
Press and hold the
Program
button on the QSE-IO for 3 seconds to exit.
World headquarters
Lutron Electronics Co., Inc.
7200 Suter Road, Coopersburg, PA
18036-1299 USA
TEL +1.610.282.3800
FAX +1.610.282.1243
Technical Support 1.800.523.9466
European headquarters
United Kingdom
Lutron EA Ltd.
6 Sovereign Close, London,
E1W 3JF UK
TEL +44.(0)20.7702.0657
FAX +44.(0)20.7480.6899
Technical support
+44.(0)20.7680.4481
FREEPHONE 0800.282.107
Asian headquarters
Singapore
Lutron GL Ltd.
15 Hoe Chiang Road,
#07-03 Tower Fifteen,
Singapore 089316
TEL +65.6220.4666
FAX +65.6220.4333
Technical hotlines
France: 0800.90.12.18
Germany: 00800.5887.6635
Italy: 800.979.208
Spain: 900.948.944
Northern China: 10.800.712.1536
Southern China: 10.800.120.1536
Hong Kong: 800.901.849
Singapore: 800.120.4491
Taiwan: 00.801.137.737
Thailand: 001.800.120.665853
Other Areas in Asia: +65.6220.4666
Daylighting setup should be performed during the daytime when there is consistent but indirect sunlight. Dark, cloudy days or days
with highly variable cloud cover that frequently changes the sunlight conditions should be avoided. Additionally, times of day when
the sunlight penetrates directly into the space should be avoided (such as morning or evening).
Note: Any zone set to “Receptacle” load type cannot be assigned to a daylight sensor.
Set Daylight Sensor Setpoint
1.
Enter Daylighting Setup.
Simultaneously press and hold the
Program
and
Input
buttons for 3 seconds. LEDs for Group 1 Inputs
and ‘Default’ for each zone will flash.
2.
Select option.
Use the
Option
button to select ‘Opt1’.
3.
Set light levels.
Use the and buttons to set the approximate light level (or, in the case of switched zones, the minimum light
level) that you wish to maintain in the space.
4.
Exit Daylighting Setup.
Simultaneously press and hold the
Program
and
Input
buttons for 3 seconds to exit.
1.
Simultaneously press and hold the
Program
and
Option
buttons for 3 seconds. Group 2 Input LEDs will flash, and the ‘Default’
LED will light.
2.
Select Scene.
Press the
Option
button to select a scene:
Scenes 1-4
LED Legend:
= steady on
= off
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
1
100%
3
50%
2
75%
4
25%
Scenes 5-16
Press and hold the
Option
button for 10 seconds, then use the
Option
button to select a scene.
LED Legend:
= flashing
= off
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
5
100%
8
100%
11
100%
14
100%
6
100%
9
100%
12
100%
15
100%
7
100%
10
100%
13
100%
16
100%
3.
Set light levels.
Use the and buttons to adjust the light level for each zone.
To make a zone unaffected, press and hold the button—the ‘High’, ‘Med’, and ‘Low’ LEDs will turn off. Continue holding until only
the ‘Med’ LED is steady on.
To make a zone affected again, press the button until you see a combination of the ‘High’, ‘Med’, and ‘Low’ LEDs steady on or
flashing.
4.
Exit Scene Setup.
Simultaneously press and hold the
Program
and
Option
buttons for 3 seconds to exit.
Note:
The fade time between scenes is factory set to 3 seconds, and is not adjustable.
Set Zone Response to Occupancy Sensors
1.
Enter Occupancy Setup.
Simultaneously press and hold the
Program
and
Input
buttons for 3 seconds. LEDs for Group 1 Inputs
and ‘Default’ for each zone will flash.
2.
Select ‘Default’.
Use the
Option
button to select ‘Default’.
Select response.
Use the and buttons to select the response type for each desired zone:
Flashing LED
Zone Response Type
High
Occupancy mode (auto on/off)
Med
Vacancy mode (manual on/auto off)
Low
Afterhours mode*
* CCI must be set up for Afterhours mode (see section
, step 3e).
3.
Exit Occupancy Setup.
Simultaneously press and hold the
Program
and
Input
buttons for 3 seconds to exit.
Select Scene for Occupied State
Note: All zones use the same ‘Occupied Scene’ and cannot be set on a zone-by-zone basis. All zones use the ‘Off Scene’ for the
unoccupied/vacant state.
1.
Enter Occupied State Setup.
Simultaneously press and hold the
Program
and
Option
buttons for 3 seconds. Group 2 Input
LEDs will flash, and the ‘Default’ LED will light.
2.
Select Scene.
Press the
Option
button to select a scene:
Scenes 1-4
LED Legend:
= steady on
= off
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
1
100%
3
50%
2
75%
4
25%
Scenes 5-16
Press and hold the
Option
button for 10 seconds, then use the
Option
button to select a scene.
LED Legend:
= flashing
= off
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
Scene
#
LED
Pattern
Default
Level
5
100%
8
100%
11
100%
14
100%
6
100%
9
100%
12
100%
15
100%
7
100%
10
100%
13
100%
16
100%
3.
Set ‘Occupied Scene’.
Press and hold the
Input
button for 3 seconds to set the currently selected scene as the ‘Occupied
Scene’. The ‘QSM’ and ‘Wired’ LEDs will turn on to indicate the selection is complete.
4.
Exit Occupied State Setup.
Simultaneously press and hold the
Program
and
Option
buttons for 3 seconds to exit.
QSE-IO Input/Output Interface Programming - continued
Daylighting Setup
Scene Setup
Occupancy Setup
QSE-IO Input/Output Interface Programming - continued
Occupancy Setup
Daylighting Setup
Scene Setup
1.
1.
1.
4.
3.
1.
4.
P
d h ld 3
d
P
d h ld
Press and hold
Press and hold
Press and hold
Press and hold
3.
4.
Press and hold
P
d h ld
2.
2.
3.
2.
2.
3.
P
Press and hold
Press and hold
Press and hold
Enter Occupancy Setup
Enter Daylighting Setup
Enter Occupied State Setup
Enter Scene Setup
Enter Scene Setup
Exit Occupied State Setup
Press
Press
Press
Press
Press
Press
Press
Press
Select Option
Select Option
Select Scene
(Scenes 1-4)
Select Scene
(Scenes 1-4)
Set Occupied Scene
Select Scene
(Scenes 5-16)
Select Scene
(Scenes 5-16)
View Scenes 5-16
View Scenes 5-16
Change Setting
Set Zone Levels
Exit Occupancy Setup
Exit Daylighting Setup
Figure
H
Figure
G
Figure
I
Figure
J