21
FK.104 (Rev.01) 19.10.2018
RTC ERROR NOTICE
Appears and remains on the lcd
persistently after a real-time-clock
error occurs.
PHASE FAILURE NOTICE
If there is no consumption record on
any phase for 30 days, it appears
on the screen. Shown on the screen
continuously.
MAGNETIC INTERVENTION NO-
TICE
Shown on the screen If there is
magnetic intervention on meter.
Stays on the screen continuously.
NOTE:
LCD screen display can be changed upon request.
5.3. Sub Menu
To display ”Sub Menu” on the screen, press and hold the menu but-
ton of the meter for 4 seconds. In the sub-menu; Voltage, Current,
Power Factor, Frequency information and previous month information
of T, T1,T2, T3, T4, Reactive inductive, Reactive Capacitive, Demand
will appear onthe screen respectively and scroll automatically. To
quit ”Sub Menu”, press and hold the menu button of the meter for 4
seconds.
Instant voltage screen
Instant current screen
cos
Instant power factor screen
cos
Instant frequency screen
Total consumed active energy in
previous month menu (T blinks)
Total consumed energy T1 ta
-
riff in previous month menu (T1
blinks)
Total consumed energyT2 tariff in
previous month menu (T2 blinks)
Total consumed energy T3 ta
-
riff in previous month menu (T3
blinks)