background image

1 2 |

P a g e

Summary of Contents for BLACKCOMB

Page 1: ...Operation Installation Instructions EQUIPMENT MODULES BLACKCOMB OWNER S MANUAL illuminating technologies for life...

Page 2: ...markets These instructions are available in soft copy via email from Luminor Customer Service CAUTION The appliance is not to be used by persons including children with reduced physical sensory or me...

Page 3: ...sition The device also can emulate the UV intensity reported by a UV sensor module Turning the right UV knob in the clockwise direction will increase the intensity while turning it counterclockwise wi...

Page 4: ...nect the controller to a PLC based system an alarm buzzer or light or an OK light Maximum contact rating is 30V 1A If the connected device eg light or buzzer exceeds the 1A current rating then use the...

Page 5: ...ote alarm solenoid module etc The 4 20 mA module must only be supplied at SELV Disconnect power supply before servicing Connect LOOP Connections as follows Sensor IEP Installation IEP connection BLACK...

Page 6: ...module requires bare leads for connection to terminal blocks so if the solenoid cable has a plug attached remove the plug and strip the wires to a suitable length INSTALLATION Step 1 Make sure the so...

Page 7: ...onnections have been made affix the male IEP plug of the solenoid module cable into the IEP port on the controller see Fig 5 or any other available IEP port such as the UV sensor 4 20 mA module or rem...

Page 8: ...lve is currently in the solenoid module incorporates three lights on the circuit board see Fig 9 When the solenoid is in the OPEN position a green light will appear on the circuit board beside the wor...

Page 9: ...vailability and use of the emergency bypass feature may be in violation of the local state provincial codes If this is the case the bypass feature can easily be disabled by physically removing the byp...

Page 10: ...isplay for additional Remote Display installation Sensor IEP Installation IEP connection BLACKCOMB Controller BLACKCOMB HO Controller IEP connection IEP connection Installation Step 1 Power off the BL...

Page 11: ...cted as a Remote Alarm on BLACKCOMB or BLACKCOMB HO controllers during the start up sequence NOTE 2 The Wireless Range can vary based on the installation environment objects walls and metal obstacles...

Page 12: ...le that contains an IEP sensor 4 20 mA module solenoid module etc plug in the included power adapter to the wall and your UV Concierge module and then restart the UV system Once the system is initiate...

Page 13: ...ting for system to complete startup You must restart your system by unplugging and plugging in the controller power cord after plugging in the UV Concierge module Once the controller detects the UV Co...

Page 14: ...1 2 P a g e...

Page 15: ...1 3 P a g e...

Page 16: ...luminating technologies for life 80 Southgate Drive Unit 4 Guelph Ontario Canada N1G 4P5 P 519 837 3800 TF 855 837 3801 F 519 837 3808 info luminoruv com www luminoruv com PN 910352 Version Date 05 20...