background image

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualied electrician.
2. Prior to installation ensure power is off at fuse box to prevent electrical shock. 

7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
[email protected]
www.luminii.com

REV0.0

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Models TAV-XX-XX

aircraft cable

standoff 
hub tab

6.3

6.2

aircraft cable

cable stopper

threaded post

6

6.1

 Untangle each aircraft cable and insert into the threaded post 

      until the cable stopper.

6.2

 Push on the standoff hub tab and feed the aircraft cable into the 

      standoff hub until necessary. Release tab to secure in place.  

For 

      the aircraft cable closest to the coaxial cable slide through the 
      o-rings on the coaxial cable first.

6.1

threaded post

5.1

 Insert the wire nut connections into the junction box & align the 

      crossbar to the junction box holes and secure using the provided 
      two #8-32 screw.

5.2

 Slide the backplate up to the crossbar and secure by hand 

      tightening the thumb nut into the crossbar. 

#8-32 screw

crossbar

backplate

junction box

5.1

5

5.2

7.1

 Tighten each threaded post into a cap, one will be on the 

      backplate and other(s) on the ceiling. If fixture not leveled, 
      adjustments can be made by pushing on the standoff hub tab. 
      Then either feed more cable into the standoff hub or pull out 
      cable from the standoff hub and release to secure.

7.2

 Cut off any extra aircraft cable from the standoff hub hole.

7

standoff 
hub tab

threaded post

aircraft 
cable

cap

7.1

7.2

7.2

8

8.1

 If necessary make any final adjustments to the cables use the 

      o-rings for a cleaner look.

8.1

o-ring

aircraft cable

coaxial cable

Page 3 of 12

Tavan

 - 

Tavan stand-alone installation

o-ring

Summary of Contents for Tavan TAV Series

Page 1: ...w luminii com Page 1 of 12 round version square version Instruction page index Tavan stand alone installation Tavan joiner installation Tavan L T or X connector installation Wiring Diagrams 2 3 4 7 8...

Page 2: ...sembly If this step if skipped coaxial cable metal sleeve will tangle up 1 while holding the coaxial cable end 2 Pull back about an 1 1 2 of the metal sleeve to expose the wires metal sleeve wires 3 C...

Page 3: ...de through the o rings on the coaxial cable rst 6 1 threaded post 5 1 Insert the wire nut connections into the junction box align the crossbar to the junction box holes and secure using the provided t...

Page 4: ...ation ensure power is off at fuse box to prevent electrical shock 7777 N Merrimac Ave Niles IL 60714 T 224 333 6033 F 224 757 7557 info luminii com www luminii com REV0 0 LUMINII RESERVES THE RIGHTS T...

Page 5: ...e provided screws 1 xture xture w joiner joiner screw 1 1 2 canopy detail 4 3 8 4 3 8 7 8 standoff cap measure measure 2 1 Note Prior to installation all wires must be present in junction box Junction...

Page 6: ...sbar assembly 5 2 Refer to the wiring diagram on page 12 and make all necessary connections junction box backplate crossbar assembly xture power wire 5 1 Note Prior to wiring the desired xture height...

Page 7: ...at fuse box to prevent electrical shock 7777 N Merrimac Ave Niles IL 60714 T 224 333 6033 F 224 757 7557 info luminii com www luminii com REV0 0 LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION IN...

Page 8: ...n ensure power is off at fuse box to prevent electrical shock 7777 N Merrimac Ave Niles IL 60714 T 224 333 6033 F 224 757 7557 info luminii com www luminii com REV0 0 LUMINII RESERVES THE RIGHTS TO CH...

Page 9: ...anopy detail 4 3 8 4 3 8 7 8 standoff cap Note Prior to installation all wires must be present in junction box Junction box must be located within 96 from the power cable on the xture Reference page 1...

Page 10: ...end through the clear o rings thumb nut backplate crossbar assembly 5 2 Refer to the wiring diagram on page 12 and make all necessary connections junction box backplate crossbar assembly xture power w...

Page 11: ...vent electrical shock 7777 N Merrimac Ave Niles IL 60714 T 224 333 6033 F 224 757 7557 info luminii com www luminii com REV0 0 LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION INSTRUCTION WITHOUT N...

Page 12: ...ing control hot blk dim hot org neutral wh ground gr rd V blk V to line voltage to LED module eldoLED 0 10V Dimming power supply wiring driver to LED module to 0 10V to line voltage rd V blk V line bl...

Reviews: