15
I
prog
(+) Pin 7
I
out
0V
20% Io
max
2V
20% Io
max
4V
40% Io
max
6V
60% Io
max
8V
80% Io
max
10V
100% Io
max
Table 2: Current Control
5.
Operating the XLB
a.
AC Input Power Connection:
Input power is shown below in Table 2.
Connect AC power connections to power supply input power terminals.
Refer to Figure 5 for location of AC Input.
MODEL
INPUT POWER
XLB-3000-XX-YY
200-240 VAC, 50/60 HZ, 18.5A @ 208VAC
Table 3: XLB-3000 AC Input Power Requirements
•
Ground wire shall be crimped to a # 8 ring-lug and connected to the
ground stud.
b.
Interface Settings
: Make sure
Interlock
, Pin 3, is connected to
GND via Interface pins 4, 9 or 15.
c.
Apply Input AC Power:
Turn ON AC power. After a few seconds the
power supply fans will begin to run.
d.
Programming Output Current:
Program the XLB-3000 power supply
for the desired output current. A 0-10V signal applied to
I
prog
, Pin 7, will
program the XLB-3000 diode driver for 0 to maximum rated output
current.
e.
Lamp On/Off:
Apply +5V to +15V to Lamp On/Off, Pin 1.
IMPORTANT APPLICATON NOTE REGARDING AC INPUT POWER
AC Input wires and Earth Ground wire should be at least
#12 AWG
; rated for at
least 300V and 105
o
C
.
IMPORTANT SYSTEM NOTE ON AC INPUT POWER
XLB-3000 units are fused on both input lines. It does not matter which of the
two AC inputs are designated Line or Neutral.
Summary of Contents for XLB-3000
Page 1: ...1 USER MANUAL XLB 3000 Short Arc Xenon Lamp Ballast...
Page 8: ...8 Figure 2 XLB 3000 Chassis Outline Drawing For 3 D model consult factory...
Page 9: ...9...
Page 11: ...11 XLB 3000 XX YY Interface Schematic Figure 4...
Page 13: ...13 NOTE Negative ignition is also available Figure 6 XLB 3000 Lamp Connections...