12
Installation and Operation of
XLB-3000 Short Arc Xenon Lamp Ballast
The XLB-3000 chassis is rack mountable and is shown in figures 2 and 5.
The XLB-3000 Igniter Module has a mounting plate shown in Figure 3.
Figure 5
XLB-3000 Input and Output Connections
IMPORTANT HIGH VOLTAGE INSTALLATION
NOTE
•
The XLB-3000 igniter module produces a 45kV pulse during lamp ignition.
The igniter module should be placed as close as possible to the Xenon lamp
in order to keep the leads between the igniter and the Xenon lamp as short as
possible. No other wires should be in the vicinity of the igniter output wires
connecting to the Xenon lamp. The HV pulse produces transients that can
be destructive to low signal electronics.
•
Please refer to Figure 3, XLB-3000 Igniter Outline Drawing, for information
regarding required clearances around the high voltage igniter coil.
SAFETY WARNING
Because XLB-3000 units are designed for OEM applications, the user must
connect AC input power to the power supply chassis. Any input AC voltage
must be considered extremely dangerous, and as such, care must be taken to
connect AC input power to the unit.