Lumin Smart Panel - Outdoor
DOCUMENTATION AND INSTALLATION MANUAL
35
PRODUCT SPECIFICATIONS
INSTALLATION
Type
Surface-Mount; Indoor or Outdoor
Installer Qualification
Local Electrical Codes and
Lumin Certified Installer
Typical Time Required
1.5
–
4 Hours
NEMA Rating
Type 3R
Temperature
-30°C to 70°C (-22°F to 158°F)
Humidity
< 100% RH
Altitude
< 3000 m
Pollution Level
Degree 3
Dimensions
55.8 cm × 48.3 cm × 14.0 cm
(22 in × 19 in × 5.5 in)
Weight
12 kg (27 lb)
Conductor Length
All Extend min 100 cm (40 in)
Beyond Conduit End
Additional Units
Use of Multiple Lumin Smart Panels
Supported
CONNECTIVITY & SECURITY
Connection Options
Wi-Fi or Ethernet
Internet Bandwidth
Approx. 0.02 Mbps
Wi-Fi Protocols
802.11 b/g/n, 2.4 GHz
Wi-Fi Encryption
WPA and WPA2 Methods
Ethernet Port
1×RJ-45 (10/100/1000 Mbps)
IP Addressing
Dynamic (DHCP)
Cryptographic System
TLS 1.2 (Minimum)
Firewall Outbound
Access Required
Ports 53, 123, 443
–
444, and 50050
–
50059
USER ACCESS
Local Network
Live Data and Controls
Applications
iOS, Android, and Web
Data
1-Second Granularity (Averaged
from 16 kHz)
Load Controls
Manually/Directly, Automated
Schedules, and Automated Modes
ELECTRICAL SYSTEM
AC Voltage
120/240 VAC Split-Phase, 50
–
60Hz
Supply Breaker Rating
15
–
20 A (non-GFCI)
Supply Amperage
0.4 A (Maximum)
Standby Power
6 W
Voltage Fluctuations
±10% from Nominal
Overvoltage
Category III (Building Wiring)
TPU (Optional)
Load Shedding: Supports Toggling
All Lines a Minimum of Once
During a Power Outage
MANAGED LOADS
Max. Load Breaker
Ratings up to 50 °C
60 A per Line × 6 Lines and
30 A per Line × 6 Lines
Load Breaker Ratings
at 50-60 °C
50 A per Line × 6 Lines and
20 A per Line × 6 Lines
Load Breaker Ratings
at 60-70 °C
40 A per Line × 6 Lines and
15 A per Line × 6 Lines
Breaker Types
Single Pole (1 Line) and Dual Pole
(2 Lines)
MEASUREMENT
Accuracy
±0.5% of Load
Monitoring Type
Separate Measurement of Lines
(Including Dual-Pole)
Split-Phase Voltage
Separate Line-to-Neutral Potential
Measurement
Current Transformers
2 Split-Core 200 A Included;
Up to 2 Additional Available
Measurement Category
Loads: CAT III (Mains Distr.)
GDC: CAT IV (Mains Source)
SUPPORT & COMPLIANCE
Warranty
10-Year Limited
Compatible Equipment
All Makes/Models/Brands of
Electrical Panels and Breakers
Safety Compliance
UL and CSA C22.2: 61010-1 &
61010-2-030
Radiofrequency
Compliance
47 CFR 15 (FCC)
RSS-Gen and RSP-100 (ISED)