RF Mux 1.0 User’s Manual
4.2.7 :SYSTem:DEBUG?
Query value of debug flags in debug register.
R
ETURN VALUE
:
Unsigned integer value containing the debug flags. See :SYSTem:DEBUG <Value> for the de-
scription of the individual debug flags.
4.2.8 :SYSTem:CONnected?
Query type of connected relay.
R
ETURN VALUES
:
A string indicating the type of the connected relay PCB, one of LSGeneric, RFMUX, LSPM or
UNKNOWN. NAN returned if no relay control PCB is connected.
4.2.9 :SYSTem:TYPE?
Query circuit types of all connected circuit boards.
R
ETURN VALUES
:
Comma separated list of strings indicating the types of all connected circuit boards, one of LS-
Generic, RFMuxA, RFMuxB, LSPM or UNKNOWN. NAN returned if no circuit board is con-
nected.
4.2.10 :OUT
Set INPUT number Na to OUTA and INPUT number Nb to OUTB.
P
ARAMETERS
:
The first unsigned integer-valued parameter sets the number of the INPUT for OUTA. If the
value exceeds the number of available input relays or is to be set to the same number as con-
figured for OUTB the command will not be processed. The second unsigned integer-valued pa-
rameter sets the number of the INPUT for OUTB. If the value exceeds the number of available
input relays or is to be set to the same number as configured for OUTA the command will not be
processed.
4.2.11 :OUT?
Query OUTA and OUTB relay configuration.
Returns two strings indicating the INPUT for OUTA and OUTB. If an output is disabled then OFF is
returned. NAN will be returned if no RF-Mux PCB is connected to the TCP-Server.
Page 14/20
2018/09/07