RF Mux 1.0 User’s Manual
4 SCPI Command Reference
4.1 Generic Commands
4.1.1 *CLS
Clear all status registers and structures, e.g. error queue.
4.1.2 *ESE <ESR>
Set event status enable register. This feature is currently not implemented.
P
ARAMETERS
:
Integer value for event status register.
4.1.3 *ESE?
Query event status enable register. This feature is currently not implemented.
R
ETURN VALUE
:
Returns the integer value of the event status register.
4.1.4 *ESR?
Query the most recent error status register value. The error will be removed from error queue.
R
ETURN VALUE
:
Value of most recent errors in error queue.
4.1.5 *IDN?
Query TCP Server identification string.
R
ETURN VALUE
:
Comma-separated string, consisting of maker, product name, product version, TCP server build
date and TCP server build time, e.g. »LUMILOOP,RFMux,1.0,Sep 2018,08:07:06«.
4.1.6 *OPC
Set operation complete flag after the completion of the previously sent command. This feature is
currently not implemented.
Page 10/20
2018/09/07