background image

6.3

 

LCD Display

6

.

3

.

1

 

Status Description

!

PV array charge ampere hours and load ampere hours are o

ff

 after power failure。

Item

Icon

Status

PV array

C

harging

PV voltage

PV current

PV ampere hours of the day

Load ampere hours of the day

The total charge ampere hours of the solar panel

Battery

Battery capacity

Battery voltage(Programmable LVD)

Battery current

Temperature(Can clear Bluetooth Device Password)

Battery type(Programmable)

Load voltage(Programmable LVR)

Load

Load current 

The total discharge ampere hours of the load

Load mode(Programmable)

Mode

6.2 Key function

Browse interface

Static display

Short press 

OK

Press the 

MENU 

and 

OK 

key at the same time for 1s, the LCD screen 

will lock the interface.  
Press the 

MENU 

and 

OK 

key again

 

for 1s, the LCD interface will unlock

and start scrolling. 

Press the 

MENU

 key for 1s to enter the setting mode when the 

icon    appears on the display interface, and exit automatically after 30s

When the controller is working in street lamp mode, press the 

MENU

 

key for 3s to turn on the load, press the 

MENU

 key again or 1min later 

the load will be turned off.

Setting parameter

Load On/Off

Operating

MENU

OK

10

Summary of Contents for Magicube Series

Page 1: ...l User Manual_Magicube series_KE CE Rohs ISO9001 2015 Subject to change without notice MPPT Solar Controller 12 24V 20 40A 260 520 1KW Magicube series Magic your solar life Lumiax www lumiax com 1 03...

Page 2: ...Mounting Location Requirements 7 5 3 Wiring Specifications 8 5 4 Connection 9 5 5 Grounding 9 6 Operation 9 6 1 LED Indicator 9 6 2 Key Function 10 6 3 LCD Display 10 6 4 Parameters setting 12 7 Prote...

Page 3: ...installing operating and monitoring Read it with special care in your own interest and please pay attention to the safety recommendations herein indicated 1 2 The manufacturer shall not be liable for...

Page 4: ...esign Extends battery life through accurate remote temperature sensor Controller is protected against over temperature due to built in power reduction function Magicube series solar controller is base...

Page 5: ...n should provide Voc vs temperature data Higher solar input voltage results in lower solar input current for a given input power High voltage solar input strings allow for smaller gauge solar wiring T...

Page 6: ...e is to offset the power consumption caused by self consumption and small loads in the whole system while maintaining full battery storage capacity In Float stage loads can continue to draw power from...

Page 7: ...3 Dimensions 3 1 The dimensions of MC2010 Unit mm 3 67 10 136 60 136 60 120 00 71 00...

Page 8: ...117 00 120 00 3 2 The dimensions of MC4010 196 50 136 60 67 10 4 Unit mm...

Page 9: ...ad Battery Terminals Connect the battery Solar module terminals Connected solar modules Heat Sink dissipate controller heat Plastic Case Internal protection LED LCD Display settings and operating stat...

Page 10: ...ontroller Modbus Communication Protocol V3 9 1 This icon in this specification indicates that this solar controller has Bluetooth communication function 2 Refer to Bluetooth APP instructions for detai...

Page 11: ...hazard that may occur Never install handle with batteries alone Avoid touching or short circuiting wires or terminals Be aware that voltages on given system components terminals or wires can be a mult...

Page 12: ...the battery voltage is between the 5 0 and 15 5 Vdc voltage range for 24 Vdc nominal voltage the battery voltage should be within the 20 0 to 31 0 Vdc range Voltages are identifiable when the controll...

Page 13: ...V system battery must be selected according to rated currents Please check following table for wiring specifications controller or between the controller and the battery are required than larger capac...

Page 14: ...current The total discharge ampere hours of the load Load mode Programmable Mode 6 2 Key function Browse interface Static display Short press OK Press the MENU and OK key at the same time for 1s the L...

Page 15: ...6 3 3 Press OK to browse the interface 6 3 2 The interface automatically cycles in the displayed sequence 11...

Page 16: ...e is 9 6 31 0V default 12 0V The low voltage recovery voltage LVR should be higher than the low voltage protection voltage LVD at least 0 6 1 2V If it is desired to improve LVD than LVR must improved...

Page 17: ...et voltage range 10 0 32 0V default 14 4V Charge recovery voltage setting range 9 2 31 8V default 14 0V Charging Voltage Parameters Li Note Overcharge Recovery Voltage 1 5V Lithium Overcharge Protecti...

Page 18: ...the controller turns off the load due to low voltage protection overcurrent protection short circuit protection or over temperature protection the load will turn on automatically when the controller...

Page 19: ...n voltage of lithium battery equals target voltage plus 0 2V the controller will stop charging to protect the battery from overcharging damage When battery voltage drops to the low voltage disconnect...

Page 20: ...ge 1 0V Voc 0 9 20A 30A Always on Street lamp User defind Mode 99 9 98 0 136 6 136 6 67 1mm 196 5 136 6 97 1mm 830g 1 3Kg 12mA RS485 RJ11 interface IoT Cyber BT Common Negative 6AWG 16mm 20 55 25 80 0...

Page 21: ...136 6 97 1mm 830g 1 3Kg 12mA Bluetooth or RS485 RJ11 interface IoT Common Negative 6AWG 16mm 20 55 25 80 0 100 RH IP32 4000m Item Max Charging Current System Voltage MPPT Charging Voltage Boost Volta...

Page 22: ...nversion Efficiency Charging Power W Charging Power W 0 0 30 60 60 120 90 180 120 240 150 300 180 360 210 420 240 480 260 520 92 92 93 93 94 94 95 95 96 96 97 97 98 98 18V 36V 36V 54V 72V 99 99 12V So...

Page 23: ...0 40 80 80 160 120 240 160 320 200 400 240 480 280 560 320 640 360 720 400 800 440 880 480 960 520 1040 92 92 93 93 94 94 95 95 96 96 97 97 98 98 18V 36V 36V 99 99 12V 18V 36V Solar Module MPP Voltag...