5, Installation
5.1 Installation Notes
⑴ This charge controller must only be used in PV systems in accordance with requirements given in this
user manual and the specifications of other system components provided by their manufacturers. No
energy source other than a PV generator may be connected to the PV charge controller referred herein.
⑵PV-modules must always be disconnected prior to the installation and adjustments of the charge
controller; Make sure the circuit breaker, fuse or disconnects of battery terminal are turned off.
⑶ Double check whether battery voltage meets the voltage range of Charge Controller.
⑷Batteries store a large amount of energy, never short circuit a battery under any circumstances. We
strongly recommend connecting a protection fuse directly to the battery terminal for protection in case of
short circuiting the battery.
⑸Batteries can produce flammable gases. Avoid provoking any sparks, using fire or any exposed flame
close to any batteries, ever. Make sure that the battery room is well ventilated to disperse any gases.
⑹Only use insulated tools and avoid placing (any) metal objects near/close to batteries.
⑺Be extremely cautious when working with batteries. Wear eye protection by all means. Have fresh water
available to immediately wash and clean any contact with battery acid. Get immediately medical aid in
case of any hazard that may occur. Never install/handle with batteries alone.
⑻Avoid touching or short-circuiting wires or terminals. Be aware that voltages on given system
components, terminals or wires can be a multiple of battery voltage. Only use insulated tools, stand on dry
ground, and keep your hands always dry and protected by proper (approved) electrician gloves when
working on PV-Systems.
⑼Prevent any water, ever, from penetrating the controller, outdoor installation must avoid any direct
sunlight and penetration of any water (e.g. rain) and humidity.
⑽After installation make sure that all connections are properly tighten, eliminate any electrical loose
connections to eliminate by all means any hot electrical connection spots.
CAUTION:
Please
read
all
instructions
and
precautions
in
the
manual
before
proceeding
with
the
installation
!
It
is
recommended
to
remove
the
protective
film
cover
from
the
LCD
screen
before
operation
.
5.2 Mounting Location Requirements
Do not subject the PV charge controller to direct sunlight or any other heat sources. Protect the PV charge
controller from any dust, dirt and moisture. Mount it flat to a vertical wall. Must be a non-flammable
material. Maintain a minimum clearance of 15 cm below and around the controller to ensure unhindered
air circulation. Mount the PV charge controller not too far from the batteries (for accurate voltage sensing
least lessening).
Mark the position of the PV charge controller fastening holes on the wall, drill 4 holes and insert dowels,
fasten the PV charge controller to the wall with the cable openings facing downwards.