Lumia Max-E Series User Manual Download Page 18

Make

 

sure

 

no

 

block

 

on

 

air

-

flow

 

around

 

the

 

controller

Clear

 

up

 

any

 

dirt

 

and

 

fragments

 

on

 

radiator

Check

 

all

 

the

 

naked

 

wires

 

to

 

make

 

sure

 

insulation

 

is

 

not

 

damaged

Repair

 

or

 

replace

 

some

 

wires

 

if

 

necessary

Tighten

 

all

 

terminal

 

screws

 

to

 

the

 

indicated

 

torque;

 

Inspect

 

for

 

loose

broken

or

 

burnt

 

cable

/

wire

 

connections.

Check

 

and

 

confirm

 

that

 

LCD

 

is

 

consistent

 

with

 

required

Pay

 

attention

 

to

 

any

 

troubleshooting

 

or

 

error

 

indication

Take

 

corrective

 

action

 

if

 

necessary

Make

 

sure

 

all

 

system

 

components

 

are

 

effectively

 

and

 

tightly

 

connected

 

to

 

ground. 

Check

 

all

 

terminals

 

for

 

any

 

corrosion

 

signs

damaged

 

insulation

increased

 

temperature

 

or 

carbonization

/

discolored

 

signs

.

Check

 

for

 

any

 

dirt

nesting

 

insects

 

and

 

any

 

corrosion

 

signs

Implement

 

corrections

 

actions

 

as

 

early

 

as

 

possible

.

WARNING:Risk of electric shock! 
                     Make sure that all the power is turned off before above operations, 
                     and then follow the corresponding inspections and operations. 

7

.3 Maintenance 

For

 

best

 

system

 

performance

the

 

following

 

inspections

 

and

 

maintenance

 

tasks

 

are

 

recommended

 

to

 

be

 

carried

 

out

 

for

 

at

 

least

 

two

 

times

 

a

 

year.

7

.

2

 

Protection

PV Short Circuit

PV Reverse Polarity 

Charging over current

The controller will limit charging current on battery to the rated level. 

When PV short circuit occurs, the controller will stop charging. 

Remove

 it to 

resume

 normal 

o

peration. 

Fully protection against PV reverse polarity, no damage to the controller.  
Correct the connection to resume normal operation.

Fully protection against battery reverse polarity, no damage to the controller.  

Correct the connection to resume normal operation.

Should there are other energy sources to charge the battery

when

 

the

 

battery

 

voltage

 

exceeds

 

15

.

8

 / 

31

.

3 / 46.8 / 62.3V

(

Overcharge

 

protection

 

voltage

 

of

 

lithium

 

battery

 

equals

 

target

 

voltage

 

plus

 

0

.

2V), the

 

controller

 

will

 

stop

 

charging

 

to

 

protect

 

the

 

battery

 

from

 

overcharging

 

damage

.

When

 

battery

 

v

oltage

 

d

rops

 

t

o

 

t

he

 

low

 

v

oltage

 

d

isconnect

 

s

etting, the

 

c

ontroller

 

w

ill

 

s

top

 

d

ischarging

 

t

o

 

p

rotect

 

t

he

 

b

attery

 

f

rom

 

o

ver

 

d

ischarging

 

d

amage

.

If the load current exceeds the maximum load current rating 1.

25

 times, the 

controller will disconnect the load. 

Once the load short 

circuit happens

 , the load short 

circuit 

protection will 

trigger

 automatically. 

The controller detects the internal temperature through internal sensor, when 
the temperature exceeds the setting value, the charging current will decrease, 
and consequently, the controllers temperature; Should controllers temperature 
rise and approach over temperature protection threshold, the controller will 
stop its operation and resume after temperature lowers/returns to an 
acceptable level.

Should

 

the

 

temperature

 

sensor

 

be

 

short

-

circuited

 

or

 

damaged

the

 

controller

 

will

 

be

 

charging

 

or

 

discharging

 

at

 

the

 

internal

 

temperature automatically

 

to

 

prevent

 

the

 

battery

 

damaged

 

from

 

overcharging

 

or

 

over

 

discharged

.

Protection

Description

Battery Reverse Polarity 

Battery Over voltage 

Battery Over discharge 

Load Over Current 
Protection

Load Short Circuit 
Protection

Over Temperature 
Protection

Damaged Remote 
Temperature Sensor 

16

!

the existing fault .

Two or more errors at the same time can damage the controller, so you must troubleshoot 

Summary of Contents for Max-E Series

Page 1: ...User Manual User Manual_Max E series_LA CE Rohs ISO9001 2015 Subject to change without notice Solar Controller 12 24 36 48V 20 30 40 50 60A Max E series 1 03 02 10019 6...

Page 2: ...ounting Location Requirements 7 5 3 Wiring Specifications 8 5 4 Connection 8 5 5 Grounding 9 6 Operation 10 6 1 LCD Display 10 6 2 Key function 12 6 3 Parameters setting 13 7 Protections Troubleshooti...

Page 3: ...nstalling operating and monitoring Read it with special care in your own interest and please pay attention to the safety recommendations herein indicated 1 2 The manufacturer shall not be liable for d...

Page 4: ...s optional Max50 60 48 E Based RS 485 standard Modbus protocol with RJ11 interface to maximize the communication needs of different occasions Max50 60 48 E Full automatic electronic protect function E...

Page 5: ...3 Dimensions 3 96 62 53 4 5 176 189 5 8 15 12 24V ATUO Solar charge controller 3 1 Max20 30 40 EU...

Page 6: ...4 Unit mm R2 25 4 4 50 4 50 138 90 187 50 177 88 5 62 50 Max50 60 E Max50 6048 E 3 2 Max50 60 48 E...

Page 7: ...ollect temperature information Temperature compensation Load Terminals Connected load Battery Terminals Connect the battery Solar module terminals Connected solar modules Heat Sink Dissipate controlle...

Page 8: ...ogram 3 Real time monitoring of PV voltage PV charging current battery voltage battery current load voltage load current and other system parameters as well as charge controller status 4 Real time aut...

Page 9: ...hazard that may occur Never install handle with batteries alone Avoid touching or short circuiting wires or terminals Be aware that voltages on given system components terminals or wires can be a mult...

Page 10: ...is adequate for the PV module operating currents Connections must always be conducted in the sequence as described below 5 3 Wiring Specifications Wiring and installation methods must comply with nati...

Page 11: ...within the 42 0 to 62 0Vdc If the polarity is correct the LCD on the controller will begin to display those 3rd step Connect the solar module When connecting the PV Module make sure to cover it from i...

Page 12: ...able LVD Battery current Battery state of charge in Temperature Clear external Bluetooth Device Password Battery type Programmable Load Fault Load current and ampere hours Load voltage Programmable LV...

Page 13: ...6 1 3 Press OK to browse the interface 6 1 2 The interface automatically cycles in the displayed sequence 11...

Page 14: ...ll be turned off Setting parameter Load On Off Operating Status Icon Description Low voltage Over voltage Battery level shows empty fault icon display battery frame flashes the LCD screen displays E3...

Page 15: ...at least 0 6 1 2 1 8 2 4V If it is desired to improve LVD than LVR must improved first 6 3 3 Clear Bluetooth Device Password For device passwords please refer to Bluetooth APP instructions 1 Lithium...

Page 16: ...12 24 36 48V 10 0 64 0V default 29 4V Charge recovery voltage setting range 12 24V 9 2 31 8V default 14 0V 12 24 36 48V 9 2 63 8V default 28 7V Charging Voltage Parameters Li Note 1 2 Overcharge Reco...

Page 17: ...to the load can be turned on or off Day Night threshold ime y Day Night threshold voltage 1 If the controller turns off the load due to low voltage protection overcurrent protection short circuit prot...

Page 18: ...nst battery reverse polarity no damage to the controller Correct the connection to resume normal operation Should there are other energy sources to charge the battery when the battery voltage exceeds...

Page 19: ...mmon positive 8AWG 10mm 20 50 25 80 0 100 RH IP32 4000m Around oblique line value separately on behalf of 12V and 24V system s value Item System Voltage Max Charging Current Fast Voltage Boost Voltage...

Page 20: ...10 6V 9 6 31 0V Lithium default 12 0V 55V Lithium Gel AGM and Liquid min 30A Always on Default Street lamp User defind Mode 138 187 5 62 5mm 720g 10mA RS485 RJ11 interface IoT Cyber BT Common Positive...

Page 21: ...ium default 29 4V 9 2 63 8V Lithium default 28 7V 9 0 60 0V Lithium default 21 0V 9 6 62 0V Lithium default 22 4V 100V Lithium Gel AGM and Liquid min 30A Always on Default Street lamp User defind Mode...

Reviews: