EN
29
Second argu
-
ment (ratio)
Second argument
for Multiplication or
Division function
-3000.0..3000.0
0.0
Low value timer
threshold
Trigger lower
threshold of acti
-
vity timer for the
virtual channel
-99999.99..99999.99
0.00
High value timer
threshold
Trigger higher
threshold of acti
-
vity timer for the
virtual channel
-99999.99..99999.99
100.00
Virtual channel
1, 2 value
Preview of the
currently calcula-
ted value for the
virtual channel,
and the saved
minimum and
maximum values
-
-
Delete channel
min/max values
Allows for clearing
the minimum and
the minimum va
-
lues for the virtual
channel
-
-
Tab
Alarm 1, 2 configuration
Alarm control
parameter
Selection of signal
to be monitored by
alarm
Not used
Analog input 1
Analog input 2
Analog input 3
Analog input 4
Virtual channel 1
Virtual channel 2
Not used
Condition type
Alarm output ope
-
rating mode. See
point 5.7. (see full
version of service
manual)
H-OFF
H-ON
N-OFF
N-ON
OFF
ON
H-OFF