NA6Plus-09
29
User’s Manual
0
Bar graph off (
OFF
)
1
Red (
r
)
2
Green (
G
)
3
Red + Green (
rG
)
Other values are only available in meters with RGB
diodes
4
Blue (
b
)
5
Red + Blue (
rb
)
6
Green + blue (
Gb
)
7
Red + Green + Blue (
rGb
)
7256 7628
dErt
w/r
-
1999...999
9
Value of change in the measured signal <
Alarm no.
>
7258 7629
d_t
w/r
0...3600
Time of change in the measured signal <
Alarm no.
>
7260
7630
Output
number
w/r
0...1
Selection of the output to be configured.
Value
0
Output no. 1
1
Output no. 2
7262
7631
Chna
w/r
0…1
Selection of channel number for analog output
<
Output no.
>
Value
0
Channel no. 1
1
Channel no. 2
7264
7632
Output
characterist
ics
w/r
0…1
Analog output characteristics <
Output no.
>
Value
0
Characteristics off
1
Characteristics on
7266
7633
X1 LED
w/r
-1999…
9999
Analog output characteristics parameters <
Output
no.
>
7268
7634
Y1 Out
w/r
-1999…
9999
Analog output characteristics parameters <
Output
no.
>
7270
7635
X2 LED
w/r
-1999…
9999
Analog output characteristics parameters <
Output
no.
>
7272
7636
Y2 Out
w/r
-1999…
9999
Analog output characteristics parameters <
Output
no.
>
7274
7637
Baud rate
w/r
0…2
RS-485 interface baud rate
Value
0
2400 bit/s
1
4800 bit/s
2
9600 bit/s
3
19200 bit/s
4
57600 bit/s
5
115200 bit/s
7276
7638
Operating
mode
w/r
1…7
MODBUS protocol operation mode
Value
0
RTU 8N2
1
RTU 8E1
2
RTU 8O1
3
RTU 8N1
7278
7639
Address
w/r
0…247
Device address selection
7280
7640
Recording
w/r
0…3
Measured value recording
Value
0
Recording off
1
Recording from channel 1
2
Recording from channel 2
3
Recording from channel 1 and 3
7282
7641
Interval
w/r
0…
99.5959
Recording time interval <
Channel number
>
7284
7642
Recording
w/r
0…
Recording start time <
Channel number
>