Programmable DC Power Supply                                                                              User’s Guide 

 

  1 

 

Introduction of Programmable DC Power Supply 

Programmable power supply is a new generation of programmable DC power supplies of 

our  factory.  The  power  supply  has  RS232  programmable  interface  and  optional  USB 

interface,  digital  nixie  tube,  LED  and  indicator  light  to  show  working  status,  key  light 

shows  setting  status.  Double  digital  knobs  and  keypad  are  supplied  to  set  parameters, 

while using of the adjusting knob, user can directly set the voltage and current and don’t 

need to switch the key and knob. The built-in function module, controlled by 32 bits MPU, 

use CAN bus-mastering to supply the reliable output and over-load hardware protection, 

the step of over-load protection is adjustable and could be selected to be on or off. Except 

of  this,  power  supply  also  protect  itself  by  warning  and  cutting  off  output  once  fun 

controlling  module  gets  fault,  transistor  over-heating,  internal  bus  gets  fault.  It  is  of 

programmable  CV/  CC  adjustable  step.  The  two  working  states,  CV  and  CC,  can  be 

switched  varying  with  the  load.  Meantime,  the  external  voltage  sampling  terminal  is 

supplied to output stable voltage for user load within the range of wire voltage drop. 

Programmable  power  supplies  are  widely  applied  in  national  defense,  institution, 

university  and  factory,  especially  in  the  areas  of  computer  measuring  and  automatic 

control system as DC power supply.   

Main function characteristics 

 

All digital control, inside CAN bus controlling, low drift and high resolution 

 

Nixie tube + LED + Key Indicator to show working state, clarity and simple 

 

User-defined storage/recall function 

 

Adjust by digital knob roughly or finely. Convenient setting and direct output   

 

Keypad lock function, to avoid the misoperation 

 

Hardware of OVP (Over Voltage Protection), setting is adjustable and ON/OFF also 

could be selected. 

 

Distanced wire voltage drop compensate, ON/OFF available 

 

Temperature fan controlling, with warning of fan/over heat/fault of internal module 

 

Standard configuration: RS232 interface   

 

Optional configuration: USB device 

 

 

Summary of Contents for HA-PSA3515

Page 1: ...PROGRAMMABLE DC POWER SUPPLY HA PSA3515 USER S MANUAL...

Page 2: ...User s Guide Programmable DC Power Supply 09 2015...

Page 3: ...ternal bus gets fault It is of programmable CV CC adjustable step The two working states CV and CC can be switched varying with the load Meantime the external voltage sampling terminal is supplied to...

Page 4: ...Programmable DC Power Supply User s Guide 2 Packing List Programmable Power Supply 1 Power Cord 1 CD User s Guide 1 RS232 interface cable 1 Optional USB interface and cable 1...

Page 5: ...t of load to power supply 10 2 7 Operation attention 11 2 8 Basic Operation 13 Chapter 3 Programmable Interface 16 3 1 To set series port 16 3 2 Programmable commands 16 Chapter4 Maintenance 17 Chapte...

Page 6: ...ter the following conditions should be achieved Voltage 115 1100 125 V 230 200 250 V Frequency 50 45 60 Hz Working Environment Indoor Temperature 0 40 Relative humidity 20 90 RH 40 Insert the power pl...

Page 7: ...na Err CC CV Output Prot set Setting 1 28 27 26 25 24 23 2 3 4 5 6 7 8 9 11 13 16 18 14 12 10 17 15 19 20 21 22 VOLTAGE CURRENT POWER SUPPLY PROGRAMMABLE V A 2 2 Keyboard Instruction 1 LCD Display the...

Page 8: ...will be saved the unit is V when finish the data input the light is off 15 Pro Enable to enable the OVP function Press the key to enable the over voltage protection with light on Press again to disab...

Page 9: ...function with light off Second function clear the over voltage protection 24 Lock Unclock to lock the keypad Press the key to lock all the keys except of Shift key Second function press Shift and Lock...

Page 10: ...rrent 4 Indicator of CV mode selected for working with light on 5 Indicator of CC mode selected for working with light on 6 Alarm indicator of failure to output as preset which indicates that the real...

Page 11: ...ower on again the power supply go on working otherwise the output will be shut off again 18 Error indicator of temperature sensor the power supply goes into protection with output disabled and need to...

Page 12: ...e function preferred terminal S and S are required to be right connected with load polarity accordingly If make wrong connection the power supply output wrong voltage and probably to burn up the load...

Page 13: ...th sense function When storage battery is used as load for long output cable user can relieve the voltage drop with sense function the connection of which is shown as figure And user must connect a di...

Page 14: ...ection circuit at output terminal If the voltage of OVP set lower than battery and OVP is enabled the thyristor is probably to breakover and cause the huge short current to burn out the mainboard So t...

Page 15: ...ion otherwise the output voltage will get higher 2 7 3 The requirement to AC power supply For the high power of this unit the transformer at power on will get a short saturation and periodic shock cur...

Page 16: ...s RPG Coarse key to change step 2 8 4 Setting of output voltage While press the OUTPUT key under presetting the output is enabled the current output voltage and current are displayed on screen If pres...

Page 17: ...o set the adjusting knob Press RPG Coarse to select 0 1V 0 1A as step for knob adjusting Press the key again to select 1mA 1mA as step for adjusting knob 2 8 13 To recall the presetting Press Recall k...

Page 18: ...al To set local control mode return 1 VOLTage NRf To set output voltage MINimum MAXimum PROTection NRf CLEar CURRent NRf MINimum MAXimum OUTPut OFF ON OUTPut MEASure MEASure CURRent MINimum MAXimum To...

Page 19: ...ructions are only for professional technicians 4 2 1 Replacing of fuse If the apparatus cannot work properly because that the fuse is burnt out first find the reason and correct and then replace the f...

Page 20: ...intaining or replacing since consignment for the verified quality problem of the product Except for this explanation and the description in the warranty card the company has no other warranty in procl...

Page 21: ...1mA 6 6 Voltage setting accuracy 0 1 10mV Voltage reading accuracy 0 1 10mV Current setting accuracy 0 2 25mA Current reading accuracy 0 2 25mA OVP setting accuracy 0 5 0 5V Note if output less than r...

Page 22: ...ment tel 48 68 45 75 139 45 75 233 45 75 321 45 75 386 fax 48 68 32 54 091 e mail export lumel com pl LUMEL S A ul Sulechowska 1 65 022 Zielona G ra POLAND tel 48 68 45 75 100 fax 48 68 45 75 508 www...