OPERATION
9. Tighten the screws securing the fence (12).
10. Loosen the Phillips head screw holding the
pointer of the mitre scale (15) and adjust it so
that it accurately indicates the zero position on
the mitre scale.
11. Retighten the screw securin
g the mitre scale
pointer.
Changing a blade
1. Make sure that the electrical plug is removed
from the power point.
2. Push down on the operating handle (3) and
pull the release knob (2) to disengage the saw
arm (1).
3. Raise the saw arm (1) to its highest position.
4. Loosen the cover plate screw about 2 turns
with a Phillips screwdriver. Do not remove this
screw from the tool.
5. Pull the rotating blade guard (6) down. When
the rotating blade guard (6) is positioned over
the upper fixed blade guard (4) it is possible to
access the blade bolt.
6. Lift and hold up the lower blade guard (6) to
expose the threaded blade bolt.
7. Hold the rotating guard (6) up and press the
spindle lock button (20). Rotate the blade until
the spindle locks.
8. Use the 6 mm hex key provided to loosen and
remove the blade bolt. (Loosen in a clockwise
direction as the blade screw has a left hand
thread).
9. Remove the flat washer, outer blade washer
and the blade.
10. Wipe a drop of oil onto the inner blade
washer and the outer blade washer where they
contact the blade.
11. Fit the new blade onto the spindle taking care
that the inner blade washer sits behind the blade.
12. Replace the outer blade washer.
13. Depress the spindle lock button (20) and
replace the flat washer and blade bolt.
14. Use the 6 mm hex key to tighten the blade bolt
securely (tighten in an anti-clockwise direction).
15. Lower the blade guard, hold the rotating lower
blade guard (6) and blade bolt cover (8) in position
and tighten the fixing screw to secure the blade
bolt cover in position.
16. Check that the blade guard operates correctly
and covers the blade as the saw arm is lowered.
17. Connect the saw to the power supply and run
the blade to make certain that it is operating
correctly.
Cross cut
If possible, always use a clamping device such as a
‘G" clamp to secure your workpiece.
When cutting your workpiece, keep your hands
well away from the blade area.
Do not remove a cut-off piece on the right-hand
side of the blade using your left hand.
A crosscut is made by cutting across the grain of
the workpiece. A 90°crosscut is made with the
mitre table set at 0°. Mitre crosscuts are made
with the table set at some angle other than zero.
1. Pull on the release knob (2) and lift the saw arm
(1) to its full height.
2. Loosen the mitre locks (18) and lifting up the
mitre latch(19) .
3. Rotate the mitre table (14) until the pointer
aligns with the desired angle.
4. Release mitre latch(19) and retighten the mitre
locks (18).