• Voltage: 12VDC (LX-1360) /
110V-120VAC (LX-1361)
• Power: 300W (LX-1360) /
330W (LX-1361)
• Motor Amps: 16A (LX-1360) / 3A
(LX-1361)
• On/Off Switch
• Flow Rate: 11 GPM (40L/Min)
• Duty Cycle: 30 Minute Continuous
• Suction: LX-1360, 10 ft. (3m) / LX-1361, 32 ft. (10m)
• Speed: 2850 RPM
• Self-Priming: Up to 10 ft. (3m) above liquid level
• Pressure: 40 PSI (3bar)
• Inlet Diameter: 3/4” (19mm), Pipe Thread
• Viscosity: Up to 1000 cps./4600 SSU max.
• Outlet Diameter: 1” (25mm), Pipe Thread
• PH (High): 8PH
• Maximum Liquid Temperature: 140°F (60°C)
• Cord Length: 6.4 Ft. (2m)
• Inlet & Outlet Connection Type: Barb
• Mounting Base (LX-1360): 3” x 2” (76 x 50mm)
2 pcs. Connectors 3/4” (19mm)
• Mounting Base (LX-1361):
4” x 3” (100 x 80mm)
2 pcs. Connectors 1” (25mm)
• LX-1360 Dimensions: 10” x 9.75” x 5.75” (270 x 245 x 142mm)
• LX-1361 Dimensions:
11.5” x 9.75” x 7” (290 x 245 x 180mm)
• LX-1360 Net/Gross Weight: 9 lbs. / 9.5 lbs. (4kg. / 4.2kg.)
• LX-1361 Net/Gross Weight:
13 lbs. / 14 lbs. (6 kg. / 6.5kg.)
Preliminary Inspection:
Verify that all components are present. Request any missing parts from Lumax.
•
Check that the Pump has not suffered any Damage during Transport or Storage.
•
Carefully clean the Suction and Delivery Inlets and Outlets, removing any dust or other packaging material
that may be present.
•
Check that the Electrical Data corresponds to those indicated on the Data Label.
•
Always install in a well illuminated area.
•
Install the Pump at a minimum height above the surface of 0.3” (0.80cm).
Positioning and Configuration:
In the case of installation in the open air, proceed to protect the Pump by
providing a protection roof.
Note:
The Pump can be installed in any position (Pump axis, vertical or horizontal). The Pump must be
secured in a stable way using the holes on the bed of the motor and vibration damping devices.
Note:
The broad range of Pump accessories make it suitable for many different uses, installations and
applications. The supporting base can be positioned in different ways.
Electrical Power Supply:
The Pump should be powered by a Safe Source and Direct Current line: Battery
or 12V Power Supply with Safety Transformer. The maximum acceptable variations from the electrical
parameters are: +/- 10% Voltage
Warning:
Power supply from lines with values that do not fall within the indicate limits could cause serious
damage to the electrical components and reduction of working performance.
Electrical Connections:
It is the responsibility of the installer to carry out the electrical connections in
compliance with the applicable regulations. Comply with the following (not exhaustive) instructions to ensure
a proper Electrical Connection:
•
Before installation and maintenance make sure that power supply to the electric lines has been turned OFF.
•
Use cables with minimum cross-sections, rated voltages and installation type that are suitable for the
characteristics of the Pump Specifications.
•
Always close the cover of the terminal strip box before switching on the power supply, after having checked
the integrity of the seal gaskets that ensure the IP55 protection grade.
SPECIFICATIONS