background image

IMPAC-Pyrometer IN 5-H-PL2

 

 

 

 

Contents 

 

General ....................................................................................... 3

 

Information about the user manual ............................................................3

 

Limit of liability and warranty ......................................................................3

 

Terminology................................................................................................3

 

Copyright ....................................................................................................4

 

Disposal / decommissioning.......................................................................4

 

Safety .........................................................................................................4

 

Appropriate use..........................................................................................4

 

1

 

Technical data ...................................................................... 5

 

2

 

Dimensions ........................................................................... 6

 

3

 

Laser targeting light .............................................................. 6

 

4

 

Optics.................................................................................... 6

 

5

 

Electrical connection ............................................................. 7

 

Connection .................................................................................................7

 

6

 

Factory settings..................................................................... 7

 

7

 

Accessories .......................................................................... 8

 

8

 

Maintenance ......................................................................... 8

 

9

 

Appendix............................................................................... 8

 

 
 

 

       Caution: Safety Advice          

 

 

Do not look directly into laser beam 

 
 
 

       Caution      

 

 

The lens has an anti-reflecting coating. 

If cleaning the lens use a soft, dry cloth such 

as that used to clean camera objectives 

 

Summary of Contents for IN 5-H-PL2

Page 1: ...IN 5 H PL2 IMPAC Pyrometer Operation Manual Betriebsanleitung Proven Quality...

Page 2: ...opriate use 4 1 Technical data 5 2 Dimensions 6 3 Laser targeting light 6 4 Optics 6 5 Electrical connection 7 Connection 7 6 Factory settings 7 7 Accessories 8 8 Maintenance 8 9 Appendix 8 Caution Sa...

Page 3: ...eneral information and notes for handling maintenance and cleaning of this instrument are offered according to the best of our knowledge and experi ence LumaSense Technologies GmbH is not liable for a...

Page 4: ...imilar instruments or was already trained by the manufacturer The pyrometer has only to be used for the purpose described in the manual It is recommended to use only accessories offered by the manufac...

Page 5: ...C measured temperature 23 C Alignment integrated laser targeting light class II total power 1 mW 650 nm focused at 100 mm Safety system IP65 with mounted connector Operating temperature 0 70 C Storag...

Page 6: ...ht The target ing light is switched on by a short push on the push button at the rear cover The laser is focused at a distance of 100 mm After 2 minutes the targeting light is turned off automatically...

Page 7: ...insolated To meet the electromagnetic requirements EMV a shielded connecting cable must be used The shield of the connecting cable is usually only connected on the pyrometer side If the connecting ca...

Page 8: ...3 834 210 Adjustable mounting support 3 835 160 Air purge unit 8 Maintenance The pyrometer does not have any parts which require regular service only the lens has to be kept clean The lens can be cle...

Page 9: ...Verwendung 11 1 Technische Daten 12 2 Abmessungen 13 3 Laserpilotlicht 13 4 Optik 13 5 Elektrischer Anschluss 14 Belegung des Anschlusskabels 14 6 Werkseinstellungen 14 7 Zubeh r 15 8 Wartung 15 9 Anh...

Page 10: ...isch gerne zur Verf gung Haftung und Gew hrleistung Alle Angaben und Hinweise f r die Bedienung Wartung und Reinigung dieses Ger tes erfolgen unter Ber cksichtigung unserer bisherigen Erfahrung nach b...

Page 11: ...anden haben Dies gilt auch wenn die betreffende Person mit einem solchen oder hnlichen Ger t bereits gearbeitet hat oder durch den Hersteller bereits geschult wurde Das Pyrometer darf nur zu dem in de...

Page 12: ...urdifferenz NETD 1 1 Tu 23 C 0 1 C bei 23 C Messtemperatur Visiereinrichtung Doppel Laserpilotlicht 650 nm ges 1 mW Laserklasse 2 nach IEC 60825 1 3 4 Schnittpunkt der Laser bei a 100 mm Pilotlicht sc...

Page 13: ...Laser pilotlicht Der Schnittpunkt der Laser ist in einer Entfernung von 100 mm Mit der Taste auf der R ckseite des Ger tes wird das Pilotlicht eingeschaltet Nach ca 2 Minuten schaltet sich das Pilotl...

Page 14: ...getrennt Um die Anforderungen der elektromagnetischen Vertr glichkeit zu erf llen EMV d rfen nur abgeschirmte Anschlusskabel verwendet werden Die Ab schirmung des Anschlusskabels wird nur auf der Pyro...

Page 15: ...alter 3 835 160 Blasvorsatz 8 Wartung Das Ger t besitzt keine Teile die einer Wartung unterliegen Die Linse kann bei Verschmutzung vorsichtig mit einem weichen trockenen Mikrofaser Tuch gereinigt werd...

Page 16: ...port lumasenseinc com LumaSense Technologies Inc 16 Thornton Road Oakland NJ 07436 Tel 1 201 405 0900 Fax 1 201 405 0090 Internet www lumasenseinc com E mail mikroninfo lumasenseinc com LumaSense Tech...

Reviews: