background image

INSTALLATION INSTRUCTIONS

FACADE OUTLINER

Vestalux

 

V2

 

LS9016

ASIA PACIFIC

  18 Brandl Street, Eight Mile Plains, QLD 4113, Australia    

P:

 +61 7 3854 5000 | 

F:

 +61 7 3854 5001 | 

E:

 [email protected]

lumascape.com.au

NORTH AMERICA

  1940 Diamond Street, San Marcos, CA 92078, USA 

P:

 +1 650 595 5862 | 

F:

 +1 650 595 5820 | 

E:

 [email protected]

lumascape.com

8 / 8

IN0184-200717

Products and specifications are subject to change without notice.

Network Topology

 – Low Voltage PowerSync™

DMX Channel Allocation

RGBA / RGBW

Single Colour

Tunable White

Pixel Size

1 ft

2 ft

3 ft

4 ft

5 ft

1 ft

2 ft

3 ft

4 ft

5 ft

1 ft

2 ft

3 ft

4 ft

5 ft

Full Fixture

4

4

4

4

4

1

1

1

1

1

2

2

2

2

2

12.0" / 300 mm

4

8

12

16

20

1

2

3

4

5

2

4

6

8

10

6.0" / 150 mm

8

16

24

32

40

2

4

6

8

10

4

8

12

16

20

3.0" / 75 mm

16

32

48

64

80

4

8

12

16

20

8

16

24

32

40

  1.0" / 19 mm

64

128

192

256

320

16

32

48

64

80

32

64

96

128

160

Extra channels required when enabling optional Advanced Control Modes.

•  Variable Dimming Smoothness Mode - requires 1 extra channel per luminaire

•  Variable Dimming Smoo Strobe Mode - requires 3 extra channels per luminaire

Maximum Circuit Loading - Single Run

LED Power

Max Leader Cable Length from 

LS6550 to first fitting

Feet of Linear luminaire per 48 V Power Supply     

120 W

240 W

320 W

480 W

600 W

4 W/ft

50 ft / 15 m

20

44

56

80

96

98 ft / 30 m

20

44

56

76

88

164 ft / 50 m

20

40

52

64

72

6 W/ft

50 ft / 15 m

14

28

36

56

64

98 ft / 30 m

14

28

36

48

56

164 ft / 50 m

14

26

34

44

48

Values in the above table show the maximum circuit loading per 48V circuit. 

Values are based on end to end spacing (ETE). Extended fixture cables, inclusion of jumper cables, or longer leader cable will effect loading. 

Circuits can be made up of up to 24 fixtures in any length, up to the maximum circuit loading in the table above. 

Circuits are limited to maximum 12.8A.

For non-continuous runs, contact Lumascape for details. 

To calculate the maximum number of interconnected luminaires per run / circuit, see example below.

Up to 24 luminaires per 48V PowerSync™ circuit / LS6550 Low Voltage PowerSync™ Data Injector

Control Resolution

Circuit Calculation Example

4 W/ft

50 m / 164 ft

20

  

For assistance, contact Lumascape.  Always observe electrical codes.

Leader Cable

20ft

4ft

4ft

4ft

4ft

4ft

20 ft of linear fixture = 5 x 4 ft luminaires

PowerSync™ Topology 1

 - Split Trunk Cable 

T

Terminator

Use PowerSync™ terminator, supplied  

with leader cable to terminate last  

luminaire in chain.

I

Maximum Current 

Through cables and connectors ≤12.8A

T

Control Signal

120-277 Vac

50/60 Hz

Power Supply  

(PSU)

LS6550 LV

PowerSync™

Data Injector

easy

glow 

tm

human

touch

tm

opti

clear 

tm

p wer

sync 

tm

grip

glass 

tm

electro

polish

+

 

tm

micro

antileach

tm

cool

drive

tm

pure

ptics

tm

I

Leader Cable

Summary of Contents for Vestalux V2 LS9016

Page 1: ...omplies with local electrical rules and regulations Input voltage range 30 48 Vdc Only use Lumascape power supply control equipment and leader cables Ensure mains input power is surge protected Never make connections while the power is connected Do not make modifications or alter the product Keep lminaire clean and free of debris Only clean with warm water Do not use chemicals or abrasives to clea...

Page 2: ...uctions The Leader Cable A connects to the first Luminaire Input B via an IP68 quick connector The LS9016 is designed for loop in loop out The output C of the previous luminaire will connect to the input B of the next luminaire At the end of the run the luminaire chain has to be terminated with a Terminator H Luminaires come with Mounting Brackets Fixed E or Adjustable D and Cable Holders G Lumina...

Page 3: ...rcos CA 92078 USA P 1 650 595 5862 F 1 650 595 5820 E info lumascape com lumascape com 3 8 IN0184 200717 Products and specifications are subject to change without notice Product Overview End View Mounting Bracket Side View Fixed Vertical Mounting Adjustable Horizontal Mounting Mounting Orientations 3 2 81 mm 3 2 81 mm 1 5 39 mm 1 5 39 mm 2 2 57 mm 3 5 89 mm 1 8 45 mm 12 7 323 mm 24 5 622 mm 36 2 9...

Page 4: ...pe com lumascape com 4 8 IN0184 200717 Products and specifications are subject to change without notice Attaching Adjustable Bracket Step 1 Step 2 Screw adjustable bracketry to mounting board on underside of luminaire and screw bracket in place Repeat until all four screws are firmly in place NOTE The adjustable mounting bracket is reversible OR Torque 1 5 N m Use allen key to loosen bracket s til...

Page 5: ...om lumascape com 5 8 IN0184 200717 Products and specifications are subject to change without notice Attaching Fixed Bracket Attaching Cable Holder Step 1 Screw fixed bracketry to mounting board on underside of luminaire and screw bracket in place Repeat until all four screws are firmly in place Torque 1 5 N m Step 1 Clip the cable under the cable holder Pinch firmly to remove and re attach cable h...

Page 6: ... in the chain When placing the luminaires in an end to end setup be sure to leave a minimum gap of 0 4 10 mm to allow for thermal expansion Minimum thermal expansion gap between luminaires 0 4 10 mm Step 1 It is recommended to mount the luminaire with 316 stainless steel screws To start put a single screw into one bracket Use a spirit level or digital inclinometer to make sure the luminaire is lev...

Page 7: ...p 1 Once the physical components have been installed it is time to complete the electrical installation Step 2 Power up the circuit to test the installation Luminaire to Luminaire Connect the output of the previous luminaire to the input of the next luminaire in the chain and tighten the connectors Do this for all the luminaires within the chain Leader Cable Connect the leader cable to the input o...

Page 8: ...48 V Power Supply 120 W 240 W 320 W 480 W 600 W 4 W ft 50 ft 15 m 20 44 56 80 96 98 ft 30 m 20 44 56 76 88 164 ft 50 m 20 40 52 64 72 6 W ft 50 ft 15 m 14 28 36 56 64 98 ft 30 m 14 28 36 48 56 164 ft 50 m 14 26 34 44 48 Values in the above table show the maximum circuit loading per 48V circuit Values are based on end to end spacing ETE Extended fixture cables inclusion of jumper cables or longer l...

Reviews: