INSTALLATION INSTRUCTIONS
FACADE OUTLINER
Vestalux
V2
LS9016
ASIA PACIFIC
18 Brandl Street, Eight Mile Plains, QLD 4113, Australia
P:
+61 7 3854 5000 |
F:
+61 7 3854 5001 |
E:
lumascape.com.au
NORTH AMERICA
1940 Diamond Street, San Marcos, CA 92078, USA
P:
+1 650 595 5862 |
F:
+1 650 595 5820 |
E:
lumascape.com
2 / 8
IN0184-200717
Products and specifications are subject to change without notice.
Bracket Mounting Orientations
A
C
B
D
E
F
G
H
Product Overview
Below is a general overview of a typical LS9016 setup. The Leader
Cable (A) connects to the LS6550 DIN Rail PowerSync™ Supply.
For details on setting-up LS6550 refer to the supply specific
installation instructions.
The Leader Cable (A) connects to the first Luminaire Input (B) via an
IP68 quick connector. The LS9016 is designed for loop-in, loop-out.
The output (C) of the previous luminaire will connect to the input (B)
of the next luminaire. At the end of the run the luminaire chain has to
be terminated with a Terminator (H).
Luminaires come with Mounting Brackets: Fixed (E) or Adjustable (D)
and Cable Holders (G). Luminaires come in 1 ft, 2 ft, 3 ft, 4 ft and 5
ft lengths. Mounting Brackets: Fixed (E) or Adjustable (D) and Cable
Holders (G) need to be attached to the luminaires before mounting.
It is recommended installers use SS316 screws per Mounting Bracket
type: 2 x Fixed (E) or 1 x Adjustable (D) to secure the luminaire to
the substrate.
COMPONENT LIST
A
Leader Cable
B
Luminaire Input
C
Luminaire Output
D
Adjustable Mounting Bracket
E
Fixed Mounting Bracket
F
Mounting Board
G
Cable Holder
H
Terminator