background image

LUMASCAPE ASIA PACIFIC

  Brisbane Technology Park, 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia

Phone +61 7 3854 5000 | Fax +61 7 3854 5001 | Email: [email protected]

www.lumacape.com

LUMASCAPE NORTH AMERICA

  1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA

Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: [email protected]

www.lumacape.com

Products and specifications are subject to change without notice.

2 / 7

 IN0167 181126 CE UL

INSTALLATION INSTRUCTIONS

INGROUND / INGRADE
LED UPLIGHT

USA I Australia I Asia I Middle East I Europe

Erden 

E8

 

LS3080

General Assembly

Luminaire Cover

After aiming luminaire at target seal luminaire using the cover. 

Align the cover screws and the screw holes in the luminaire body 
with the corresponding threaded holes in the pre-installation kit.

Be sure to tighten cover screws as per the torque pattern shown 
above.

Luminaire Body

Slide into pre-installation kit and secure to mounting collar using 
cover and cover screws.

Ensure all sealing surfaces 
are clean and free of 
concrete, dirt, debris or any 
other foreign matter. Sealing 
Surfaces include.

Cover Screw(s)

Tighten in the following torque pattern to seal luminaire.

Foam Plug

Use as a temporary barrier 
when concrete is poured 
around pre-installation kit.

Remove before installing 
luminaire to allow for 
adequate drainage.

Poured Concrete

Temporary Cover

Keep on pre-instalation kit 
in order to avoid concrete 
and debris from entering 
the cavity. Remove when 
ready to installl luminaire.

1

 Entire Rubber Lid Seal

2

 Luminaire Flange

3

 Luminaire Lid Uderside

torque order

1

2

6

5

3

4

Aiming Luminaire

Ensure all Sealing Surfaces are Clean

A

2

3

1

C

B

D

D

A

 

Aim Mark

 

Point in the direction of the target to be lit.,

B

 Rotation Lock Screw

 

Tighten to lock gimbal rotation.

C

 

Tilt Adjustment Screw

 

Turn to adjust tilt of gimbal.

To prevent condensation, ensure 
luminaire is acclimatized (at same 
temperature as environment) before 
installation.

Wiring Details

CE Color Code

UL / ETL Color Code Designation

 Green / Yellow

 Green

Earth / Ground

 Brown

 Black

Active / Live

 Blue

 White

Neutral

 Black

 Grey

Data *

* Data wire must be appropriately insulated if not connected.

Operating voltage on this wire is 24 V. Incorrect wiring will 
damage luminaire and void warranty.  Do not Hi-Pot test.

L

N

Bootlace ferrules must be ued on all wires when 
connecting in terminal blocks.

Luminaire Cable / Hookup Wire

Terminate in accordance to local wiring rules.
Make sure to properly isolate data wire if not used.
See diagram below for conductor colour and designation.

Mounting Collar

Ensure final installation surface is completely flush with top 
face of the blockout.

Gravel 

Use gravel which allows good drainage around luminaire.

Mounting Brackets

Screw mounting brackets to collar to arrest any movement.

Summary of Contents for LS3080

Page 1: ...before installation or maintenance may result in fire serious injury electric shock death and may damage the luminaire READ ALL SAFETY INSTRUCTIONS FIRST Warranty Void if not installed as per installation instructions and in compliance with the local electrical code N653 LS3080 LS640 K84 Pre Installation Follow instructions carefully failure to do so will void warranty Ensure installation complies...

Page 2: ...uminaire to allow for adequate drainage Poured Concrete Temporary Cover Keep on pre instalation kit in order to avoid concrete and debris from entering the cavity Remove when ready to installl luminaire 1 Entire Rubber Lid Seal 2 Luminaire Flange 3 Luminaire Lid Uderside torque order 1 2 6 5 3 4 Aiming Luminaire Ensure all Sealing Surfaces are Clean A 2 3 1 C B D D A Aim Mark Point in the directio...

Page 3: ...IONS INGROUND INGRADE LED UPLIGHT USA I Australia I Asia I Middle East I Europe Erden E8 LS3080 Component Overview Installation Preparation WARNING The luminaire should only be used complete with its protective shield cover Keep electronics free from dirt and moisture Luminaires can become very hot Use discretion in placement No power tools to be used Do not shorten or interfere with cable assembl...

Page 4: ... to next PowerSync Data Injector Up to 45 luminaires per run Max run length 492ft 150m Consult voltage drop and run length tables for specific limitations When no data injector is in use non dimming applications isolate data wire When no data injector is in use non dimming applications isolate data wire For last luminaire in the circuit install terminating resistor in parallel across the data wire...

Page 5: ...ns Always observe NEC branch circuit current limitations When no data injector is in use non dimming applications isolate data wire When no data injector is in use non dimming applications isolate data wire For last luminaire in the circuit install terminating resistor in parallel across the data wire and earth wire 120 277 V 50 60 Hz Junction Box Junction Box Termination Junction box or other app...

Page 6: ...y details and lamp type if applicable Position and use screws to attach brackets at the bottom of the mounting collar before concrete is poured Fit sleeve collar and cover plate Fit sleeve and collar over foam plug Ensure enough cable is in the cavity to connect to luminaire Position top surface of the mounting collar to be flush with final surface level Screw cover plate to mounting collar Ensure...

Page 7: ...ard pressure on gimbal tighten rotational lock grub screw Lay lid partially over luminaire to allow a gap for any moisture present to evaporate prior to sealing Connect to supply and allow to burn for 2 hours IMPORTANT Do not energise without partially covering gimbal Alternatively using heat gun set at 100 C heat the inside of luminaire at a distance of 300mm away for 10 minutes Seal immediately ...

Reviews: