WARNING
Turn off power supply to avoid risk of electrical shock. This fixture must be wired in accordance with the National Electrical Code
and all applicable local codes and ordinances. Proper grounding is required to ensure personal safety. All work must be done by a
qualified electrician.
INSTALLATION
To ensure proper installation and service, the fixture should be mounted with the lamp in a horizontal position. Do not recess. Also,
weatherproof the fixture by sealing all gaps and holes with weatherproof silicone sealant.
DIRECT MOUNTING USING CONDUIT
1. Extend glare shield (1) to its fully extended position.
2. Loosen 2 lens screws (2) located at each corner of the fixture and open lens.
3. Remove the reflector (5) by removing the two reflector retaining screws (4).
4. Locate and remove the desired conduit plug (8) on the top or sides of the fixture housing (7).
5. Mount fixture to wall using vertical side (A) by drilling through the housing approximately 1/2" (13mm) from each corner (12) at the back of
the fixture and securing it to the mounting surface.
6. Attach conduit and pull supply leads through the conduit.
7. All unused holes must be sealed. Apply waterproof silicone to all mounting holes to ensure a tight seal.
8. Wire to the power source and ground (refer to wiring instruction below).
9. Replace reflector (5), install lamp (3), and close lens.
10. Adjust glare shield (1) as desired.
MOUNTING TO JUNCTION BOX
1. Extend glare shield (1) to its fully extended position.
2. Loosen 2 lens screws (2) located at each corner of the fixture and open lens.
3. Remove the reflector (5) by removing the two reflector retaining screws (4).
4. Locate and remove the center knockout plug (8) on vertical side (A). Drill holes in appropriate bosses located on angled side to match
junction box hole pattern.
5. Route supply wires through conduit and secure fixture to junction box. Note: When mounting in wet locations, a junction box rated for wet
locations must be used.
6. All unused holes must be sealed. Apply weatherproof silicone to all mounting holes and between the fixture and mounting surface to ensure
a tight seal.
7. Wire to the power source and ground (refer to wiring instruction below).
WIRING
Turn off power supply at the main fuse/ breaker box.
1. Determine the supply voltage the fixture will be connected to.
2. 23Y145 is factory set to the highest voltage (277V). If another voltage is desired, remove the wire nut from the voltage lead desired and
place the wire nut on the voltage lead that will not be used. Note: All leads are appropriately identified with either labels or have printing on
the insulation of the leads.
3. Connect the desired voltage lead (11) (120V, 208V, 240V or 277V) for the fixture to the voltage supply lead.
4. Connect the lead from the fixture printed (13) (COM) to the common supply lead.
5. Connect the supply ground lead (10) to the fixture ground screw (14) (GREEN).
6. Insulate all unused leads with wire nuts.
MAINTENANCE
Turn off power supply before installing or servicing fixture.
1. When replacing the lamp (3) in this fixture, always turn off and give ample time for lamp to cool.
2. Never operate the fixture if missing any glass, the safety shield, or the safety grill.
3. Always use the appropriate lamp (3) for the fixture.
4. UL approved wire connectors should be used. No loose strands should stick out from under the wire connectors.