Mitel SX200D ONS (77135)
C o n f i d e n t i a l
8
The above information is provided by Lucent Technologies as a guide.
See disclaimer on page 1
Lucent Technologies
O c t e l M e s s a g i n g D i v i s i o n
6.0
CONFIGURATION OF THE LUCENT OCTEL 50
Sections 6.1 show the integration codes that should already be configured for
your switch. Setup sections may be checked to verify that this is done.
If the integration codes are not correct, run the Integrator program and select the
Mitel SX200 Digital ONS switch.
6.1
OCTEL 50
Outside Line Access Code
9,
Off Hook Delay (OFFHDLY)
50
Hook Flash Interval (FLINTVL)
50
DTMF Tone Length (TONELEN)
8
Message Waiting Parameters
Permit Message Waiting Lights
9
Message Waiting Light Prefix ON
(see section 5.5)
*41
Message Waiting Light Prefix OFF
(see section 5.5)
*42
Inband Parameters
Total Number of DID Digits
10
Seconds to Wait for First Digit
2
Millisecs to Wait for Next Digit
500
Inband Parameters
Total Number of DID Digits
10
Seconds to Wait for DID
2
Location of Inband Signaling Code
1
Number of Milliseconds to Wait for Digits
500
Code for Go to Immediate Record
7
Start at End of String for Go to Immediate Record
Enabled
Location of Mailbox Number for Immediate Record
3
Code for Go to Voice Mail
4
Start at End of String for Go to Voice Mail
Enabled
Location of Mailbox Number for Go to Voice Mail
3
Code for Immediate Subscriber Login to Mailbox
8
Start at End of String for Immediate Login
Enabled
Location of Mailbox Number for Immediate Login
3
Code for Busy Extension
2
Start at End of String for Busy Extension
Enabled
Location of Mailbox Number for Busy Extension
3
Code for No Answer Extension
3
Start at End of String for No Answer Extension
Enabled
Location of Mailbox for No Answer Extension
3
Start at End of String for Default Code
Enabled
Location of Mailbox Number for Default Code
3
Note: Verify all above dialing sequences for your switch. Refer to
section 5.4 for switch programming for this function.
Lucent Octel 50 Configuration
Integration for Octel 50