DEFINITY ECS Release 6
System Description Pocket Reference
555-230-211
Issue 2
January 1998
Page 87
Power Supply Unit Load
Power Supply Unit Load Requirements (
continued
)
Unit Load Rating of System Modules
*
012 modules older than 517H13 may have a unit load up to 8.4.
†
This is a MERLIN II loop-start-only module that can be used in the MERLIN
LEGEND Communications System.
Module
Unit Load
Module
Unit Load
008
12.0
408 GS/LS
12.0
008 MLX
13.5
408 GS/LS-MLX
12.0
008 OPT
8.0
408 (LS)
12.0
012 T/R
7.2
*
800 GS/LS
0.0
016 T/R
12.8
800 GS/LS-ID
0.0
100D (DS1)
0.0
800 (LS)
†
0.0
400 GS/LS/TTR
0.0
800 DID
8.0
400 (LS)*
0.0
800 NI-BRI
0.0
400EM
8.0
Processor
0.0