8-6 Issue 9 October 1998
363-206-204
Releases 9 and 11 Installation Tests
DDM-2000 OC-3 Command Notes
All DDM-2000 OC-3 commands will be issued through the ASCII terminal.
Commands can be entered in either upper or lower case (or a mixture).
If a command is partially entered, or if a ? is entered any time, the user will be
prompted with a menu of available choices.
A complete list of DDM-2000 OC-3 command codes with their descriptions is
contained in the 363-206-280,
DDM-2000 OC-3 Multiplexer User/Service Manual
.
The following special ASCII characters are supported:
■
Semicolon (;) — Official and preferred man machine language (MML) com-
mand terminator.
■
Carriage Return, Enter, or Dollar Sign ($) — Alternative MML command
terminators.
■
Question Mark (?) — Suspends the present input operation and displays
appropriate help which requires a user response.
■
Backspace and Underbar (_) — Erases the previous character input.
■
At-sign (@) — Erases the current line.
■
CANcel, and DELete — Terminates the current input line or currently run-
ning command.
■
Hyphen (-) — Separates identifiers in the command mode.
■
Colon (:) — Separates parameter blocks in a command.
■
Comma (,) — Separates parameters within a parameter block in a com-
mand.
Login Procedure
1. Connect one of the approved terminals (properly configured) to an EIA-
232D port on one of the DDM-2000 OC-3s in the bay.
NOTE
:
If properly cabled, connection to any EIA-232D in the bay will allow com-
munication to any shelf in the bay.
2. Press the Return (or Enter) key twice, to set the SYSCTL autobaud rate
and prompt the DDM-2000 OC-3 to request a shelf address.
The DDM-2000 OC-3 will respond:
/* Enter a shelf number from 1 to 8 */
shelf [default] =
Summary of Contents for DDM-2000 OC-3
Page 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Page 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Page 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Page 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Page 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Page 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Page 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Page 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Page 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Page 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Page 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Page 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Page 492: ...IN 14 Issue 9 October 1998 ...