3-4
Preliminary cvMAX-100 Hardware Installation Guide
Navigating and Securing the Interface
Security profiles
Setting enumerated parameters
An enumerated parameter has a set of predefined values. You modify it by simply placing the
cursor beside the parameter and pressing the Enter, Return, or the Right-Arrow key until the
proper value appears.
Saving your changes
When you exit a profile after changing any of its settings, a message prompt asks if you want
to save the changes.
EXIT?
>0=ESC (Don’t exit)
1=Exit and discard
2=Exit and accept
You can save the profile values by choosing the Exit and Accept option and pressing Enter, or
by pressing the 2 key.
Security profiles
The cvMAX-100 has nine security profiles, which you can configure to provide up to nine
levels of security. When you first receive your cvMAX-100, none of the profiles implements
any restrictions.
To see the list of Security profiles:
1
From the Main Edit Menu, move the cursor to the System menu and press Enter.
2
Move the cursor to Security and press Enter.
The Security menu appears:
00-300 Security
>00-301 Default
00-302
00-303
00-304
00-305
00-306
00-307
00-308
00-309 Full Access
Assigning privileges
Turning the the cvMAX-100 power on activates the Default profile, which is the first Security
profile in the Security menu. Default profile has no password. As an administrator, you should
reset the privileges in the Default profile to restrict the functions for users accessing the
cvMAX-100 configuration menus. You should also change the password of the Full Access
profile. Do not change any other settings in the Full Access profile. Proceed as follows:
1
Open the Default profile.
2
Select Operations and set this privilege to
No
.