NOTE
– To comply with regulations, installation must be carried out
by qualified electrician and in accordance with the current IEE Wiring
Regulations (BS7671) and Building Regulations. A copy of the instructions
must be left for the user/maintenance engineer for future reference.
ENSURE ELECTRICAL SUPPLY IS DISCONNECTED/
ISOLATED BEFORE COMMENCING INSTALLATION
INSTRUCTIONS FOR NEW INSTALLATIONS
1. This luminaire requires a cut-out of 63 - 70mm, it is
recommended that the luminaire is installed in a 67mm cut-out.
The cut-outs need to be spaced to provide adequate clearance
from beams, pipes and electrical cables.
2. Twist bezel anti-clockwise to remove the bezel and LED module
for installation.
3. Insert ceiling bracket by lifting the springs to vertical and insert
into ceiling cut-out. Ensure the bracket assembly is positioned
centrally in the ceiling cut-out.
4. Pull electrical cables through the bracket. Recommended 20mm
of insulation and 5mm conductor length.
5. Wire mains and lamp to terminal block, ensuring correct polarity
of live/neutral. Downlight = Blue - Neutral, Brown - Live.
6. Align points on the bezel to ceiling bracket springs, insert and
rotate clockwise until tight.
7. Re-instate power and test.
PART CODE:
LFR5WH255D40 / LFR5PC255D40 / LFR5BS255D40 / LFR5PC250D27 / LFR5WH250D27 / LFR5BS250D27
LFR7WH475D40 / LFR7PC475D40 / LFR7BS475D40 / LFR7PC450D27 / LFR7WH450D27 / LFR7BS450D27
Tech Help Line
UK -
0845 194 7584
Non UK -
+44 (0)1952 238 100
Visit our website at
Luceco is a registered trade mark of Nexus Industries Ltd.
Supplied by
BG Electrical Ltd
Stafford Park 1 TF3 3BD ENGLAND
www.luceco.co
LED
Fire Rated
Downlight
Installation & Operating Instructions
V2KS-01/2014
•
Suitable for use with mains voltage of 180-240V AC.
•
This luminaire is compatible with most leading edge dimmers such as BG Electrical Triac Dimmers; please
check with dimmer manufacturer for compatibility with LED lighting, including min/max wattage loads.
•
Luminaire is only suitable for covering with blanket/roll type loft insulation material only.
•
IP65 rated luminaires are protected against dust and jets of water; it is suitable for installation in bathroom
zones 1 and 2 as defined by the IEE Wiring Regulations. IP65 only when installed as per instructions.
•
This luminaire is only suitable for indoor use.
•
This luminaire must be disconnected before insulation resistance testing of the lighting circuit.
•
Check for electrical cables and pipes before installation.
CRI
80
>
IP65
RATED
7
GUARANTEE
year
extended
90
min
FIRE RATED
60
min
FIRE RATED
30
min
FIRE RATED
50,000
HOURS
1
SCALE 1.000
3
SCALE 3.000
L
L
N
N
20mm
5mm
5
6
SCALE 1.000
4
SCALE 1.000
Cable
SCALE 1.000
Align
points on
the bezel
to ceiling
spring.
Mains
Downlight
2
67mm
Blue
Brown