LUCCI 210019 Installation Instructions Manual Download Page 6

Installation Instructions 

 

 

 

6 | 

P a g e  

 

    

 

 

 

Troubleshooting 

 
Warning:

 For your safety, ensure the power is switched OFF before starting the troubleshooting procedures 

 

Specifications

 

SKU# 210019 

         Transmitter (Remote): 

     Receiver   (Controller) : 

Model No 

UC7070T 

Model No 

UC7076R 

Rated Voltage 

1x9V battery 

Rated Voltage 

240VAC 50Hz. 70mA 

Frequency 

433.92MHz 

Max. Motor 

0.5A 

 

 

 

Max. Incandescent/halogen 

load 

300W 

 

 

 

Max. Fluorescent lamp & 

ballast load 

300W 

TROUBLE 

PROBABLE CAUSES 

SUGGESTED REMEDY 

1

No functions operate 

 

Warning:

 Some task can 

only to be performed by a 

qualified technician. 

Main power not restored 

Replace fuse. Turn ON circuit breaker. Turn 

ON wall switch. 

Wall controller is not removed and 

interferes with remote operation. 

Remove the fan wall controller, and 

replace with ON/OFF switch for remote 

Wall switch power to the fan 

remote is OFF. 

Switch wall switch ON, to power the 

remote. 

Receiver wiring incorrect. 

Verify wiring connections according to 

label and wiring diagram. 

Transmitter and receiver DIP 

switches do not match 

Set transmitter and receiver to same DIP 

switch setting. 

The remote is too far from the 

receiver 

Move closer to receiver 

2. Remote LED/LCD no 

display

 

Battery too weak 

Replace with all new batteries. Do not mix 

up the old and new battery. 

Battery at wrong polarity 

Reinstall the battery at right polarity 

The contacts in battery 

compartment are corroded or bent. 

Clean corroded contacts. 

Bend contacts back to their correct 

position. 

Poor contact with batteries. 

Roll the batteries to well sit in the 

compartment. Or replace with other brand 

batteries. 

3. Operates only at close 

range 

Signal blocked from reaching 

receiver 

Extend antenna out from canopy, or move 

it for better reception 

Battery too weak 

Replace with all new batteries. Do not mix 

up the old and new battery. 

4. More than one fan 

operates interference at 

same area. 

RF interference 

Change DIP switch settings to a different 
code. Each pair of transmitter and receiver 
must have unique DIP switch code. 

Summary of Contents for 210019

Page 1: ...Select a suitable location for installation This product is suitable for indoor use only This ceiling fan remote controller is only suitable for controlling the fan motor and the light kit associated...

Page 2: ...ode combinations This is practical when there is more than 1 remote receiver pair operating locally or in the same room Fig 1 Battery compartment Fig 2 Dip switch Installing the receiver FOLLOW THESE...

Page 3: ...ol unit 11 Lay the control unit in the CANOPY See Fig 4 12 Reinstall the canopy on the mounting bracket 13 Restore electrical power to the circuit Fig 3 Fig 4 NOTE Fan installation must be complete in...

Page 4: ...ent light dimmer function with the Fan that has Remote Control device to avoid damage to the Remote as following If the Remote Control device is to be installed with an existing ceiling fan with any o...

Page 5: ...transmitter will flash when the buttons are active BUTTONS ON THE REMOTE HI Press the button to set fan running at High speed MED Press the button to set fan running at Middle speed LOW Press the but...

Page 6: ...g incorrect Verify wiring connections according to label and wiring diagram Transmitter and receiver DIP switches do not match Set transmitter and receiver to same DIP switch setting The remote is too...

Page 7: ...eglect or been involved in an accident 2 The repairs are not required as a result of normal wear and tear 3 The product was installed by a licensed electrical contractor 4 A copy of the original recei...

Page 8: ...RRANTY HOTLINE 1800 602 243 Complete and retain this form for your personal records and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER PO DATECODE Sticker here PO NUMBER or DATECODE DATE OF PURC...

Reviews: