Lucci LEDlux Project 180298 Installation Instructions Download Page 4

Installation Instructions 

 

4  | 

P a g e  

 

v 1 . 0        

 

Safety Tips 

 

Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning or 

making any adjustment to the fitting. 

 

To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power.   

 

Select a suitable location away from liquids and hazards. 

 

Ensure that the fitting does not come in contact with corrosive chemicals, etc. 

 

To clean, wipe with a damp clean cloth. Never soak the fitting with water. 

 

Handle the fitting and cover/shade with care to avoid breakage. 

 

 

 

Troubleshooting

 

PROBLEM 

POSSIBLE CAUSE 

SUGGESTED SOLUTION 

Does not work.   

(New installation) 

Wiring loose or no power to the LED 

fitting. 

Check your circuit breaker/safety switch box and 

turn on power to your circuit. 

Contact the installing licensed electrician to check if 

the fitting has been installed correctly. 

Does not work. 

(Existing installation) 

No power to the LED fitting. 

Check your circuit breaker/safety switch box and 

turn on power to your circuit. 

Contact your nearest Beacon Lighting store. 

 

 

 

Specifications

 

SKU # 

180298 

Insulation Class 

Class I 

Rated Voltage 

220-240V~ 50Hz 

Rated Wattage 

23W 

LED Specs 

SEOUL LEDs,    non-dimmable 

4000K,    1300lm 

Weight 

0.7kg 

Dimensions 

H:105mm    Dia:350mm 

Serviceable Parts 

LED driver Model#: QM-SY5800-12X2W-D58 

 

Summary of Contents for Project 180298

Page 1: ...installation of the light fitting must adhere to local and national wiring rules eg AS NZS 3000 2007 Amendment 2 2012 Electrical installations This is a Class I fitting and must be earthed during installation Select a suitable location for installation This product is suitable for indoor use only The mounting point must support 2 times the weight of the fitting Ensure the fitting is not installed ...

Page 2: ... mounting surface 5 Remove the cover from the terminal block and connect the mains supply wire to the terminal block Figure D Mains Supply Wire Fitting Wire Earth Yellow Green Yellow Green Neutral Blue or Black Blue Live Brown or Red Brown Ensure that the wires are secure and no bare wires are exposed Install the cover back over the terminal block NOTE A loop terminal is provided on the terminal b...

Page 3: ...D DRIVER 1 Ensure the power is off figure A 2 Remove the shade from the fitting by rotating it anti clockwise Figure B 3 Unplug the input and output wire connectors from the old LED driver Figure C 4 Remove the LED driver from the lamp base by loosening 2 screws on the side Figure C 5 Install the new replacement LED driver by tightening the 2 screws and reconnect the input and output wire connecto...

Page 4: ...th care to avoid breakage Troubleshooting PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Does not work New installation Wiring loose or no power to the LED fitting Check your circuit breaker safety switch box and turn on power to your circuit Contact the installing licensed electrician to check if the fitting has been installed correctly Does not work Existing installation No power to the LED fitting C...