30
4)
Place the removed gasket around the filter
circumference in place. Remove the cap of a new
cartridge, and then mount the cartridge by
turning it clockwise. Discharge a small amount of
grease from the cartridge before mounting it.
Refer to "5-2 Replacement of grease
cartridge."
When the filter is replaced, some air
enters into the pump. Be sure to bleed air.
Refer to "6-1 Bleeding air."
(2)
Filter for 7C-LD, 7C-LFBD (531402)
Replace the filter once in about two years or at the time of
replacing around ten cartridge containers; we recommend
the more frequent one.
1)
Wipe out grease attached around the filter, and
then hold the filter between two fingers to
remove it by turning it to the left or the right. If
it is too difficult to pick up the filter up with your
fingers, use a tool such as pliers to pinch the
filter to remove it by turning it to the left or the
right.
When using a tool such as pliers, be careful
not to pinch the filter too hard and damage
the cartridge adapter.