Caution
Illustration of Screen
About Maintenance
◆
Failure to follow instruc�ons may result in danger.
◆
The charging sta�on shall be operated by adults only.
◆
Do not dissemble the charging sta�on while it’s opera�ng.
◆
Install a charging sta�on away from pyrotechnics, dusty or corrosive places.
◆
Only use the charging sta�on when it’s normally opera�ng and please strictly follow the instruc�ons.
◆
The charging sta�on produces high voltage output. You must pay a�en�on to personal safety when using it.
◆
If malfunc�on happens, it may cause electric shock or even death. Under emergency situa�ons,
you can cut off the power supply.
In order to ensure the normal service life of the charging sta�on and reduce risk, maintenance
must be performed within the specified �me. The maintenance of the equipment must be
completed by professionals with qualifed and safe maintenance tools.
The product is already packed in factory. During transporta�on, strong impact and bumps should
be avoided to avoid damage to the outer packaging of the product.
The product should be placed at an ambient temperature of -40
℃
~
55
℃
with a rela�ve
humidity of no more than 95%. The air should not contain acids, alkalis ot other corrosive gases
and explosive gases.
1.Real�me effect in kW
3.Charging session dura�on
5.Charging anima�on
1.Fault message
2.Unit temperature
Note:
When problems occur, the wallbox will automa�cally restart to try to fix the
problem and con�nue charging.
2.Voltage and current pr phase
4.kWh charged
6.Temperature
EV Charger
L1
:
223V 15.18A
L2
:
219V 15.35A
L3
:
220V 15.11A
Short Circuit
00:02:06
0.30Kwh
24.1
℃
EV Charger
29.4
℃
9.5
KW
!
1
5
6
2
1
2
3
4