![LU-VE Alfa LU-VE AlfaBlue Junior AG Instruction Manual Download Page 10](http://html1.mh-extra.com/html/lu-ve/alfa-lu-ve-alfablue-junior-ag/alfa-lu-ve-alfablue-junior-ag_instruction-manual_1945302010.webp)
AHE00060EN 2010
10
Alfa LU-VE is a trademark registered and owned by LU-VE Group.
Alfa LU-VE reserves the right to change specifications without prior notification.
Total amount of lifting points
(identical for both horizontal and vertical airflow models)
351, 501, 631:
4 lifting points
352, 502, 632
4 lifting points
353, 503, 633:
4 lifting points
504, 634: 6 lifting points
635: 8 lifting points
636: 8 lifting points
30° max
30° max
side view
AlfaBlue Junior heat exchangers can be lifted
from above. For models with 2 or more fans the
use of a hoisting beam is required. AG/XG63
models are supplied with lifting lugs. For other
models eye bolts must be fitted on all lifting
points.
Attach belts or hooks to the lifting point. Respect
the allowable chain angles. The load on the lift
-
ing chains shall be equally distributed on all the
lifting points.
For all heat exchanger models it is mandato-
ry to use all indicated lifting positions during
any lifting operation.
4.4 Lifting from above
M8 eye bolts
to be fitted on
AG/XG 35/50 models
(not provided)