Safety Instruction

 

These  instructions  are  intended  to  ensure  that  user  can  use  the  product  correctly  to  avoid  danger  or  property 

loss. 

 

The precaution measure is divided into “Warnings” and “Cautions” 

Warnings: 

Serious injury or death may occur if any of the warnings are neglected.

 

Cautions:

 

Injury or equipment damage may occur if any of the cautions are neglected.

 

 

 

 

 

Warnings

 

 

Proper configuration of all passwords and other security settings is the responsibility of the installer and/or 

end-user. 

 

In the use of the product, you must be in strict compliance with the electrical safety regulations of the nation 

and region. Please refer to technical specifications for detailed information. 

 

Input voltage should meet both the SELV (Safety Extra Low Voltage) and the Limited Power Source with 

100~240 VAC or 12 VDC according to the IEC60950-1 standard. Please refer to technical specifications for 

detailed information. 

 

Do not connect several devices to one power adapter as adapter overload may cause over-heating or a fire 

hazard. 

 

Please make sure that the plug is firmly connected to the power socket.     

 

If smoke, odor or noise rise from the device, turn off the power at once and unplug the power cable, and then 

please contact the service center.   

 

 

Warnings

 Follow these safeguards to prevent 

serious injury or death.

 

Cautions 

Follow these precautions to 

prevent potential injury or material 

damage. 

 

Summary of Contents for POE-SW1602

Page 1: ...POE SW1602 POE SW2402 User Manual...

Page 2: ...WILL OUR COMPANY ITS DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS B...

Page 3: ...dance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the use...

Page 4: ...safety regulations of the nation and region Please refer to technical specifications for detailed information Input voltage should meet both the SELV Safety Extra Low Voltage and the Limited Power Sou...

Page 5: ...properly secured to a rack or shelf Major shocks or jolts to the unit as a result of dropping it may cause damage to the sensitive electronics within the unit Use the device in conjunction with an UP...

Page 6: ...or purchasing our product If there is any question or request please do not hesitate to contact dealer The figures in the manual are for reference only This manual is applicable to the models listed i...

Page 7: ...e Installation 11 2 1 Installation Notes 11 Safety Alert 11 Environmental Requests 11 Tools 12 2 2 Installation 12 Rack mounting 12 Desktop mounting 13 2 3 Grounding 14 With grounding bar 14 Without g...

Page 8: ...oE output is 230W POE SW1602 and 370W POE SW2402 By using Cat 5 twisted pair the device can provide data and power for APs IP cameras IP phones and other PoE devices Moreover with using Cat 5e Etherne...

Page 9: ...t is connected with a PD Powered Device and powers the PD properly Blinking The PoE output of the corresponding port exceeds 30W Off The corresponding port is no PoE power output or no PD connected PO...

Page 10: ...e and configure the speed and duplex of the remote device to be Auto Negotiation 2 If Extend mode is disabled the transmission distance of PoE powering and data is up to 150m by using Cat 5e or better...

Page 11: ...SW2402 as a guide Figure 1 2 POE SW2402 Power Socket Used for connecting the included power cord for power supply Please use the included power cord to connect the device to power supply Grounding Ter...

Page 12: ...from the power supply when you are to do the cleaning Position the device away from strong current Cautions There is a seal covering one of the screws in the case of the device In case of need repair...

Page 13: ...the instructions below The rack desktop is stable and sturdy enough Place the device in a clean dry and well ventilated environment Keep at least 10cm free on all sides for cooling Do not place any he...

Page 14: ...re 2 2 L shaped bracket installation 3 Adjust the device to a nice height and fix the device to the rack with screws self prepared Shown as below Figure 2 3 Fix to the rack Desktop mounting Also you c...

Page 15: ...If a grounding bar is available at the installation site follow either of the two installations to ground the device A Connect to the Grounding Bar Directly 1 Connect one end of the grounding cable t...

Page 16: ...in the equipment room Do not connect it to a fire main or lightning Without grounding bar If there is no ground bar but earth nearby and the grounding body is allowed to be buried follow below steps 1...

Page 17: ...ounding body are not available an AC powered Ethernet switch can be grounded using the PE Protecting Earth wire of the AC power supply Figure 2 8 Ground with 3 core AC power cord Cautions Make sure th...

Page 18: ...be wireless AP IP phone or IP camera etc By default PoE features of Ports 1 16 24 are enabled Figure 3 1 RJ45 port connection Note that 1 Cat 5e or better Ethernet cable is recommended As each RJ45 p...

Page 19: ...fiber into the TX Figure 3 3 Insert optical fiber 3 3 Check the Cabling Once installation is completed check the cabling of the device as the following The operating power supply should accord with r...

Page 20: ...port Figure 3 4 Lightning protector connection Ethernet cable Grounding terminal Lightning protector Grounding cable Outdoor cabling 3 4 Connect to Power Supply Please use the included power cord for...

Page 21: ...Supported Lightning proof Ranking RJ45 port lightning proof 4KV Power source lightning proof 6KV Power Input 100 240V AC 50 60Hz Physical Environment Operating Environment Temperature 0 40 Humidity 10...