30
4.11 Operating pad
The integrated 128x64 pixel graphic display on the front displays the course of interesting data
such as feed power. The required parameters can be selected and entered via the 8-key operating
pad. The operating pad lights up when the first key is pressed and turns dark again after 5 minutes.
F1: Display the menu.
◄►
: Function in the menu: jump to the first or last menu item.
Function while parameters are edited: digit to the left, digit to the right (decade jump).
▲▼
: Select the menu.
ESC: Acknowledge failures and delete entries.
: Confirm the selected menu and entered data.
4.12 Internal Data Logger
The LSPV inverter features an internal data logger that allows measured values to be
simultaneously recorded in the form of parameters. The data logger is implemented as a ring buffer.
If this buffer is full, the oldest data is overwritten. With the default setting on delivery, the data
logger logs 16 measuring channels.
Recording cycle
Storage time
1 minute
6 months
2 minutes
12 months
5 minutes
2,5 years
10 minutes
5 years
Status LED