17
3.3 Transport
The devices must be transported under clean and dry conditions, if possible in their original pack-
aging. The transport temperature must be between –25 °C and +70 °C. Permissible variations in
temperature may not exceed 20 K per hour.
3.4 Storage
The devices must be stored in clean and dry rooms, if possible in their original packaging. The
storage temperature must be between –25 °C and +55 °C. Permissible variations in temperature
may not exceed 20 K per hour.
Note:
The LSPV inverter contains electrolyte capacitors which can be
stored for no more than 2 years and at a storage temperature of
≤
40 °C while they are in a de-energized state.
If the storage time of two years has been exceeded, please contact
the LSIS Service before connecting the LSPV inverter to your system!
3.5 Mounting the LSPV inverter 010K to 020K
Mount the inverter by means of the self-centering wall-mounting plate which is included in the
scope of delivery.