![background image](http://html1.mh-extra.com/html/lsc/gen-vi/gen-vi_installation-and-operation-manual_1943921018.webp)
Menu System
GenVI Dimmer
Operator Manual V1.0
Page 14
The menu shows the first 6 channels. Use the
<
or
>
buttons to see the other groups of 6
channels. Touch a channel to select it. You can select multiple channels. To select a range of
channels select your first channel then press
Thru
then your last channel. Use
All
to select
all channels. Press
None
to de-select all channels.
When you have selected your channel(s) press
Set Address
.
Enter the required DMX address then press
Apply
.
If more than one channel is selected, then the lowest channel number will be patched to the
selected DMX slot and the following dimmers will be patched to the sequential DMX slot
numbers.
For example, if channels 1, 2, 3 and 10 are selected and DMX slot number 24 is applied the
result will be ……
Channel DMX Slot
1
24
2
25
3
26
10
27
To patch multiple channels to the same DMX slot patch them one at a time.
When finished patching press
Exit
.
If dimmer channels have been individually patched, then the “DMX Address” home page
displays a table showing the patches. For example:
3.8.2
16 Bit DMX Control
The DMX512-A signal contains the level information for 512 DMX slots (addresses). The
level for each slot is sent in 8 bits of data which gives a maximum resolution of 256 discrete