Page 7
This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
The Inverter
Drive Supermarket and must not be reproduced or altered without prior written permission.
©
NPN
PNP
RUN
STOP/RST
FWD
REV
min
max
NPN
PNP
RUN
STOP/RST
FWD
REV
min
max
6.4 Use the left and right arrows on the navigation pad
to move between digits. Use the up and down arrows to
increase or decrease the digit value.
In this example, the motor nameplate states 4.7A at 230V
so we will change the default value from 5.0 to 4.7.
LS Industrial Systems SV-iC5
Easy Start Guide
NPN
PNP
RUN
STOP/RST
FWD
REV
min
max
6.5 Press the navigation pad to save changes. Press
the navigation pad again to confirm.
Once the value of H33 has been changed to 4.7 press the
navigation pad to save changes.
The display will then flash indicating that the change needs
to be confirmed.
Press the navigation pad again to confirm the change or
wait to cancel the change and return to the edit screen in the
previous step.
Press up to
change to 0 to 7
Press down to
change 5 to to 4
Press left to
change digit
6.6 Parameter value is set.
Now H33 has been successfully set. The screen will return
to the parameter list.
Repeat the steps above to set the value of other
parameters. See section 4 for recommended settings.
Press the left or right keys on the navigation pad to return to
the Drive Group (ie. the group which does not start with F, H
or I).