background image

15

 

 

     Disposal 

 

 

7

 

Disposal

 

The remote control and the control 

unit contain electronic components, 

cables, metals, plastics etc. and must 

be disposed of in accordance with 

the applicable environmental 

regulations of the respective country.

 

This symbol on the product or its 

packaging indicates that the product 

may not be disposed of via the 

household waste system.

 

Users have a duty to dispose of the old 

equipment via the collection point for 

electronic and electrical scrap.

 

Separate collection and correct 

disposal of your old equipment helps 

conserve natural resources and 

guarantees recycling, which protects 

human health and preserves the 

environment.

 

Please contact your local council or 

waste disposal authority to find out 

where the collection points are for 

your old equipment.

 

Disposal of the radio remote control in 

Germany is subject to the Electrical 

Equipment Act, internationally to the 

EU Directive 2011/65/EU RoHS or the 

respective national laws.

 

(The product is not subject to the EU 

Directive 2002/96/EC (WEEE) and its 

supplement EU Directive 

2003/108/EC.)

 

Disposal of batteries in the EU is 

subject to the Battery Directive 

2006/66/EU, in Germany to the Battery 

Act (BattG) dated 25.6.2009, and 

internationally to the respective 

national laws.

 

Summary of Contents for VFF/CDL-CF-15

Page 1: ...Radio remote control VFF CDL CF 15 with Bluetooth Technology Operating Instructions ...

Page 2: ...2 Foreword Foreword Revision history Version Date 1 0 18 03 2020 Change First edition In your own interest Read these operation instructions and keep them in a safe place Observe the safety instructions ...

Page 3: ...uctions 6 2 4 Information about radio operation 7 2 5 Handling Batteries 8 2 6 Electronic medical equipment 8 3 Commissioning Operation 9 13 3 1 The remote control 9 3 2 The control unit 10 3 3 Inserting the batteries 10 3 4 Teach in process 11 3 5 Initial position 11 3 6 Bed adjustment 12 3 7 Memory positions 12 3 8 Torch function 13 3 9 Reset to factory settings 13 4 Malfunctions troubleshooting...

Page 4: ......

Page 5: ...repairs and failures These operating instructions were compiled with great care No liability will be assumed for the accuracy and completeness of the data images or drawings unless prescribed by law Subject to technical amendments that serve continuous product improve ment without prior announcement 2 Safety instructions The radio remote control can be used by children aged 8 and upwards and by pe...

Page 6: ...be used with a medical product or installed in a medical product in an environment in which there are inflammable or explosive gases or vapours e g anaesthetics in damp environments outdoors in applications that are washed in mechanical washing systems for lifting and lowering of loads in craftsman or industrial areas or in the household 2 3 Specific safety instructions Caution The following safet...

Page 7: ...herwise the warranty will become void Operation The remote control only functions correctly if it is commissioned and used properly To avoid injury never allow children or other vulnerable persons to use the remote control unsupervised Radio signals can pass through walls and ceilings Only use the remote control in the room in which the adjustablebed islocated 2 4 Information about radio operation...

Page 8: ...es and goggles should be worn when replacing leaking batteries Avoid touching leaking batteries with your bare hands as far as possible Should you come into contact with leaked battery components wash your hands thoroughly Remove any electrolyte residues by damp wiping Wash any clothes that come into contact with the electrolyte 2 6 Electronic medical devices This product is designed and manufactu...

Page 9: ...9 Comissioning 3 Comissioning Operation 3 1 The remote control ...

Page 10: ... the battery compart ment as shown in the picture Ensure that the batteries are inserted in the right direction Once the batteries have been inser ted close the battery compartment lid again and the radio remote control is operational 1 Optional not to be operated with this remote control Inbetriebnahme ...

Page 11: ...The back adjustment motor moves briefly up down The status LED s goes off the keypad illumination lights up constantly Theteach inprocesshas been completed successfully If the status LED s and the keypad illumination do not flash but a connection between double drive and remote control is still not established bed cannot be adjusted the double drive and remote control must be reset to the factory ...

Page 12: ...tons 11 or 12 The current position is assigned to the corresponding memory button and saved Recalling memory positions Caution Before using the memory buttons Check that neither you nor anyone else or any pets are at risk from the moving parts of the adjustment mechanics Stored positions can be recalled with the memory buttons Proceed as follows Press one of the buttons 11 or 12 and keep it presse...

Page 13: ... hold the buttons 1 3 and 5 or 2 4 and 6 The status LED starts flashing When the status LED is steady release the buttons The status LED goes off the remote control is reset Resetting the double drive Press button L on the double drive for approx 10 s The drive for the leg adjustment moves briefly to confirm a reset to the factory settings Remove the plug from the mains socket and wait for at leas...

Page 14: ...ess again see page 11 Reset the control unit to the default settings see page 13 and then carry out the teach in process again see page 11 5 Technical data Operating voltage 3VDC via batteries Power consumption Idle typ 1µA Operational 2mA Transmission freq 2 4GHz ISM Band Transmission range 10 50m Housing material ABS Protection grade P20 Battery type 2 pcs 1 5V AAA LR03 Weight incl batteries and...

Page 15: ... equipment helps conserve natural resources and guarantees recycling which protects human health and preserves the environment Please contact your local council or waste disposal authority to find out where the collection points are for your old equipment Disposal of the radio remote control in Germany is subject to the Electrical Equipment Act internationally to the EU Directive 2011 65 EU RoHS o...

Page 16: ...erved It is strictly forbidden to duplicate this document in any form without the prior consent of the company LS Bedding nv LS Bedding nv is not liable for any errors in this document or for any ensuing damages connected to the delivery performance or use of this material ...

Reviews: