Thermoregulator
(Water Type) User Manual

Summary of Contents for TRG-BS-12

Page 1: ...Thermoregulator Water Type User Manual ...

Page 2: ...l www facebook com ekinendustriyel www youtube com ekinendustriyel www linkedin com company ekinendustriyel www soundcloud com ekinendustriyel www twitter com ekinendustriyel www spotify com ekin endustriyel Follow us on social media ...

Page 3: ...estioning of the status quo and our desire to outperform ourselves New Generation Engineering With our engineering approach that focuses on the process not the problem we do not just specialize in a product we consider the entire ecosystem of that product Ergo we produce all the other components of a system in addition to plate heat exchangers and we focus on the constant development of engineerin...

Page 4: ...ulators Pasteurizers CIP and Hygienic Process Systems Hygienic Storage and Process Tanks Homogenizers Turn key Projects Water Heater Tanks Water Storage Tanks Buffer Tanks Expansion Tanks Stainless Steel Tanks Balance Tanks Dirt Separators Air Separators Air Tubes Steam Separators Pressured Air Tanks Neutralization Units Lobe Pumps Hygienic Centrifugal Pumps Twin Screw Pumps Gear Pumps Magnetic Dr...

Page 5: ...Contents InstructionManual 1 Working Principle 2 Controller 3 Menu Entry 4 First Start Up 4 Power Connection 6 Mold And Water Connections 7 Y Type Water Filter 8 ...

Page 6: ...erature thermostat 6 All parts used in the device are stainless and resistant to heavy duty and corrosion 7 MIT TRG S series mold heater operates up to maximum temperature of 120 C 8 Operation and maintenance can be carried out with convenience thanks to its easy to remove outer casing General Features Coolant system pressure will be between 2 and 5 bars MODEL MIT TRG S 6 MIT TRG S 9 MIT TRG S 12 ...

Page 7: ...prevent water leakage Outputs should be evaluated from technical drawings first After making the cooling tower connections of the cooling inlet of the mold heater open all the valves 3 Turn on the main switch and the low level lamp will light up with an audible alarm The MIT TRG S series automatically fills up water until this alarm stops 4 Check the direction of pump rotation If it is reverse mov...

Page 8: ...ds an audible signal and the system stops Check if the engine runs smoothly Check if there are three phases Reset the thermal relay 4 High Temperature Light When the temperature of the water in the system exceeds 120 C it gives an audible warning and stops the system to protect it Hot water in the tank should be drained and filled again 5 Low Water Light When the water level in the device is decre...

Page 9: ... Output Mode 2 Sub Heating 3 Cooling Temp 1 H Limit Temp 2 L Limit Temp 3 Temp Unit 4 Temp Degree 5 Ctr Temp Bias 6 Ret Temp Bias 7 Ent Temp Bias 1 Current Time 2 Auto st Week 3 Auto st Time 4 Maint time 5 Work Time 1 Protocol 2 Address 3 Bps 4 Data Length 5 Stop Bit 6 Parity Bit 1 Language 2 Remote 3 Password 4 Red Ent Disp 5 W Fill Tm T1 6 W Fill Tm T2 7 Version 1 Turn main switch ON 2 Turn pump...

Page 10: ...0 0 C Heating control time setting Cooling control time setting PBC cooling proportional band setting Heating proportional band setting Integral time setting Differential time setting 1 PB 2 TI 3 TD 4 PBC 5 CT 6 CTC Control Control MIT TRG S Series Mold Heater can be adjusted up to a maximum temperature of 120 C WARNING Check the direction of rotation of the pump 5 The device automatically adjusts...

Page 11: ...6 Power Connection ...

Page 12: ...e device are shown in Figure 2 Water from the water tower or chiller must be connected to the cooling water inlet Cooling water outlet should also be connected to the return line of the water tower or chiller To remove the top cover of the device lift it up as shown in the picture To remove the side covers of the device pull it as shown To reach the parts in the electrical panel of the device unsc...

Page 13: ...n audible warning 1 Missing oil or water 1 Check the system for leaks 2 Add oil or water to the system OVERLOAD light is on 1 Blocked pipeline 2 Low voltage 3 Broken pump 1 Clean the pipeline 2 Stabilize the voltage 3 Replace the pump Draining system does not work 1 Magnetic valve is broken 1 Repair or replace with new The coolant pressure should be 2 bars It should not be higher than 5 bars at an...

Page 14: ... Check the alarm system Date Check operating functions Check all electrical connections Check all electrical cables Check if the Y type filter is clean Check the solenoid valve Check the alarm system Date Check operating functions Check all electrical connections Check all electrical cables Check if the Y type filter is clean Check the solenoid valve Check the alarm system Date Check operating fun...

Page 15: ...presentative importer or manufacturer of the goods 4 In case of malfunction of the goods within the warranty period due to material workmanship or assembly defects the goods will be repaired at no cost and no additional cost will be asked from the buyer under the name of changed part price or any other name 5 Malfunctions arising from the use of the product in contravention of the provisions in th...

Page 16: ...11 CERTIFICATES ...

Page 17: ...12 ...

Page 18: ... SERVICE Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on Follow us on F...